Before replacing the lamp, unplug mains lead and let the lamp cool down (approx. 5 minutes).
During the installation do not touch the glass-bulbs bare-handed! Please follow the lamp manufacturer's
notes!
Do not install lamps with a higher wattage! Lamps with a higher wattage generate temperatures the device
was not designed for. Damages caused by non-observance are not subject to warranty.
For the installation, you need one of the following lamps, depending upon device version:
OMNILUX JTT 230V/100W E27 1000h 2800K
OMNILUX JTT 230V/150W E27 1000h 2800K
OMNILUX JTT 230V/200W E27 1000h 2800K
OMNILUX JTT 230V/300W E40 1000h 2800K
OMNILUX JTT 230V/500W E40 1000h 2800K
OMNILUX JTT 230V/750W E40 1000h 2800K
OMNILUX JTT 230V/1000W E40 1000h 2800K
OMNILUX JTT 230V/1500W E40 1000h 2800K
OMNILUX JTT 230V/2000W E40 1000h 2800K
Procedure:
Step 1: Unscrew the cover screws.
Step 2: Remove the cover.
Step 3: If replacing the lamp, remove the old lamp from the lamp holder.
Step 4: Insert the lamp into the lamp holder.
Step 5: Replace the cover.
Step 6: Tighten the cover screws.
Overhead rigging
Please consider the EN 60598-2-17and the respective national standards during the installation!
The installation must only be carried out by an authorized dealer!
DANGER TO LIFE!
Only install the lamp with the device switched off!
Unplug from mains before!
CAUTION!
The lamp has to be replaced when it is damaged
or deformed due to the heat!
Do not operate this device with opened cover!
DANGER TO LIFE!
15/34
88020000
88020001
88020002
88020003
88020004
88020005
88020006
88020007
88020008
00019835.DOC, Version 1.1