Routine Maintenance

Regularly clean the water filter at the injector inlet and the fertilizer suction filter.
If its planned not to operate the injector for a long period, operate the injector for a few minutes
with the metering tube immersed in a tank with clean water to remove fertilizer residues from the
injector preventing them solidifying in the injector.
If there is fear of frost and the temperature falling below 4°C (39°F) empty the water from the
injector. To do this, close the entry and exit valves securely. Open and dismantle the 3/4" record
that connects the suction pipe. Press the suction check valve using a finger or a thin rod, allowing
all the water that has collected in the injector to drain out while pressing the air release valve at
the top of the injector.
Problem
The injector does not
work
The injector has
stopped working
There is a leak from
the injector.
There is no suction.
TEFEN
TEFEN Advanced Plastic Solutions.

Troubleshooting Guide

Check
The injector is fitted with the arrows in the
opposite direction to the water flow.
The inlet and outlet valves are closed.
The inlet filter is blocked.
There is no water flow at the appropriate
pressure.
There is no water flow at the appropriate
pressure. Open the main valve. Open the nut
locking the motor cover, remove the motor
cover, and remove the mechanism. Check if
the motor seals are defective.
Check if the springs are broken.
Check if the seals above the valves are
defective or have been displaced.
Check if one of the parts of the mechanism
is broken.
The leak is from the connection between the
body and the cover.
The leak is from the connection of the
suction tube.
The leak is from the non-return valve.
The suction filter is blocked.
Dismantle the injector unit and check if the
suction seal is defective.
The non-return valve is defective.
Fit The injector with the arrows in
the direction of the water flow.
Open the valves
Clean the filter.
Open the main valve.
Replace the motor seals.
Replace the springs.
Replace the seals.
Replace the broken part.
Open and remove the motor
cover, replace the seal, fit the
cover, and thoroughly tighten the
cover locking nut.
Remove the suction tube, replace
the defective seal and reconnect.
Dismantle the non-return valve
and replace the defective seal.
Clean the filter.
Replace the suction seal.
Replace the non-return valve.