COMMISSIONING
As for the fixed application, please apply four screws to tighten the equipment on the
foundation support firmly.
When the equipment is used for the pound and swimming pool in the garden, the equipment
shall be subject to the special setup to avoid the overflow and falling.
The equipment shall be installed in the well-ventilated places to avoid the weather effect. In
case of indoor operation, please ensure that the floor is equipped with drainage ditch or
leak- age-proof mechanism.
Please check the suction hose and guarantee its airtightness before startup. When the air
foam is absorbed in the hose, the equipment is likely to be out of order because the leakage
exists possibly.
Danger
All interfaces which are connected to the suction pipeline shall be sealed by hemp and thick slurry or
sealing tape. The leak- age will reduce the air exhaust.
The interface of metal pipe thread shall be sealed by sealing tape.
All components of suction pipeline shall be installed by professionals.
The inner diameter of suction pipe shall be 25mm at least; The suction pipe shall be kinking resistant
and suitable for the vacuum environment.
Considering that the increasing pipe length will reduce the transmission capacity, the suction pipeline
shall be as short as possible.
The suction pipeline shall uplift the pump steadily to avoid any bubble.
Please ensure that the suction pipeline has enough water supply; The terminal of suction hose shall be
submerged in water all the time.
All components of pressure pipeline shall be compressive.
All components of pressure pipeline shall be installed by professionals.
Danger type and source:
In order to avoid any mechanical force or tension, the suction
pipeline shall be installed. When the transmission pipeline is
polluted, please apply filter to make cleaning and protection.
Attention:
We advise to install one check value to avoid the equipment
shutdown which is caused by water loss absence during the
pump.