2 ROUTE CONDUIT THROUGH
CUTOUT
CAUTION
Two people are required to
lift the oven into the opening. Grasp the bottom
at front and rear. Discard foam base. DO NOT
USE HANDLE OR CONDUIT TO LIFT THE
OVEN. DAMAGE WILL OCCUR.
PRECAUCIÓN
Se requiere contar con dos
personas para colocar el horno en la abertura. Se
deberá tomar la parte inferior sobre la parte frontal
y trasera. Descarte la base de gomaespuma. NO
USE LA MANIJA NI LOS CONDUCTOS PARA
LEVANTAR EL HORNO. SE PRODUCIRÁN
DAÑOS.
With oven in front of the cabinet opening:
• Insert conduit into cabinet opening. Connect
oven wiring and branch circuit.
• Lift the oven into the opening while continuing to
feed the conduit in the direction of the installed
junction box. Be sure the conduit does not get
pinched between the back of the oven and the
cabinet wall.
• Leave oven a few inches forward of the cabinet
front frame. Do not push the unit all of the way
into the cutout.
WARNING
• Disconnect power to the junction box before
making the electrical connection.
• Electrical ground is required on this appliance.
• Do not connect the electrical supply until
appliance is permanently grounded.
ADVERTENCIA
• Desconecte la corriente de la caja de
empalmes antes de realizar la conexión
eléctrica.
• Este electrodoméstico requiere que se realice
una conexión a tierra.
• No conecte al suministro de corriente hasta
que el electrodoméstico se haya conectado a
tierra de forma permanente.
Installation Instructions
(Oven shown without
accessory storage drawer.)
GROUNDING INSTRUCTIONS
This appliance must be connected to a grounded,
metallic, permanent wiring system, or an
equipment grounding connector should be run
with the circuit conductors and connected to the
equipment grounding terminal or lead on the
appliance.
Failure to follow these instructions could result
in fire, personal injury or electrical shock.
2 ROUTE CONDUIT THROUGH
CUTOUT (CONT.)
When connecting to a 3-conductor branch
circuit:
• Connect oven red lead to branch circuit red
lead.
• Connect oven black lead to branch circuit black
lead.
• Connect oven green ground lead and white lead
to branch circuit neutral (white or gray).
When connecting to a 4-conductor branch
circuit:
• Connect oven red lead to branch circuit red
lead.
• Connect oven black lead to branch circuit black
lead.
• Break connection between oven white lead and
oven green ground lead.
• Connect oven white lead to branch circuit neutral
lead (white or gray).
• Connect oven green ground lead to branch
circuit ground lead (green or bare copper).
11