... the green light flashes on
and off ...
... the appliance fails to cool
the air properly ...
... the appliance is switched
on but the compressor is
not running ...
... the appliance makes a lot
of noise ...
38
The appliance and the remote control are out of
synch. Turn the appliance on using the remote
control to re-synchronise them again
automatically.
Make sure that the connections on hot-air expulsion
duct are in working order.
Make sure that the expulsion duct is not
excessively bent or longer than 140 cm.
Make sure that drainage stopcock is set to the
temperature control position.
Use the suction pad to make the opening on the
window as small as possible.
Lower blinds if available to reduce direct sunlight.
Whenever the appliance is switched on, the 3-
minute switch-on delay is activated. T h e
compressor will then start audibly after 3 minutes.
Room temperature must exceed 18°C in order for
the appliance to work in the air-conditioning
(cooling) and dehumidification modes.
Make sure that the air extraction duct is properly
fitted onto the appliance.
Make sure that the appliance's air inlets and outlets
are free from obstruction.
If the noise sounds like water flowing, then this is
due to the pump which circulates water around the
system so as to enhance the efficiency of the
appliance.
Warning!
Any other kind of fault or repair work must be
dealt with by a specialised technician. Contact
your authorised supplier, the after-sales service or
the Technical Service Network.