17 - PROGRAMMING THE CONTROL
UNIT
-PrG
The configuration menu
items; the display shows the selected item.
i
By pressing
, you will pass to the next item; by pressing
will return to the previous item.
By pressing OK, you can view the current value of selected item
and possibly change it.
FinE
The last menu item (
) allows storing the carried out changes
and going back to the control unit normal operation.
You must exit from programming mode through this menu item if
you do not want to lose your configuration.
m
WARNING: in case no operation is carried out for more
than one minute, the control unit exits from the
programming mode without saving any of your setups and
changes, which will get lost.
i
h
By holding down the
or
keys, configuration menu items will
FinE
scroll fast, until item
is viewed.
In this way, you can quickly reach either the top or bottom of the
list.
PARAMETER
VALUE
dir
dX
SX
t.PrE
0.5" - 1'00
no
t.P.Ch
0.5" - 1 '00
no
P.AP
30 - 100
P.Ch
30 - 100
FrEn
no
Si
consists in a list of configurable
h
, you
DESCRIPTION
Direction
Set up the functioning directions.
This parameter must be set up based on the RIGHT or LEFT installation
of the barrier (chapter 5)
Installation on the right (DX)
Installation on the left (SX)
Pre-blinking time
Before any barrier movement, blinker will be activated for
warn about the incoming motion
Function deactivated
Different closing pre-flashing time
If this parameter has a value assigned to it, the control unit will activate
pre-flashing prior to closure for the length of time set in this menu
(adjustable time from 0.5" to 1'00)
The closing pre-flashing time corresponds to
Motor power in opening phase
The displayed value is the percentage of max. motor power
Motor power in closing phase
The displayed value is the percentage of max. motor power
Brake function
This function allows to block immediately the boom after a command or
the intervention of a security device.
Because of the inertia, the boom does not immediately stop its movement
and can last for a few centimeters, compromising the safety of the
automation.
NOTE: the brake function is not activated at the limit switches area
Function deactivated
Function activated
-PrG
t.PrE
t.PrE
- 52 -
FinE
dir
t.PrE
DEFAULT
MEMO
dX
1.0"
time, to
no
80
70
Si