The following form lists the common operation system with problem and solutions.
Please read the form carefully and follow it.
WARNING!
If any of the following symptoms appears during your operation, stop using the tool
immediately, or serious personal injury could result. Only a qualified persons or an
authorized service center can perform repairs or replacement of tool.
Disconnect tool from air supply before attempting repair or adjustment. When replacing
O-rings or Cylinder, lubricate with air tool oil before assembly.
SYMPTOM
Air leak near top of tool or in
trigger area
Air leak near bottom of tool.
Air leak between body and
cylinder cap.
Blade driving fastener too deep.
Tool does not operate well: can
not drive fastener or operate
sluggishly.
Tool skips fasteners.
Tool jams.
PROBLEM
1.O-ring in trigger valve are
damage.
2.Trigger valve head are damage.
3.Trigger valve stem ,seal or
O-ring are damaged.
1. Loose screws.
2. Worn or damaged O-rings or
bumper.
1. Loose screws.
2. Worn or damaged O-rings or
seals.
1. Worn bumper.
2. Air pressure is too high.
1. Inadequate air supply.
2. Inadequate lubrication.
3. Worn or damaged O-rings or
seals.
4.Exhaust port in cylinder head
is blocked.
1.Worn bumper or damaged
spring.
2.Dirt in front plate.
3.Dirt or damage prevents
fasteners from moving freely in
magazine.
4.Worn or dry O-ring on piston
or lack of
lubrication.
5.Cylinder cover seal leaking.
1.Incorrect or damaged fasteners.
2.Damaged or worn driver guide.
3.Magazine or nose screw loose.
4.Magazine is dirty.

TROUBLESHOOTING

SOLUTION
1.Check and replace O-ring.
2.Check and replace.
3.Check and replace trigger valve
stem, seal or O-ring.
1.Tighten screws.
2.Check and replace O-rings or
bumper.
1.Tighten screw.
2.Check and replace O-rings or
bumper.
1.Replace bumper.
2.Adjust the air pressure.
1.Verify adequate air supply.
2.Place 2 or 6 drops of oil into
air inlet.
3.Check and replace O-rings
or seal.
4.Replace damaged internal parts.
1. Replace bumper or pusher
spring.
2.Clean drive channel on front
plate.
3.Magazine needs to be cleaned.
4.O-ring needs to be replaced.
And lubricated.
5.Replace Sealing washer.
1.Change and use correct
fastener.
2.Check and replace the driver.
3.Tighten the magazine.
4.Clean the magazine.
7