SYMPTOM
No heat, fan runs
Propane Portable Heaters Manual

TROUBLESHOOTING

PROBABLE CAUSE
Rear of heater blocked
Rear of appliance
If the rear of the heater is obstructed,
the ¾" snap disc manual reset limit
may trip and must be reset manually
before the fan can operate
Rear of appliance exposing ¾"
snap disc manual reset limit
switch.
Faulty On-Off switch
REMEDY
Ensure rear of heater is unobstructed
and proper rear clearances are main-
tained (see approval label for specifi-
cations).
Carefully remove the panel screws.
The high temperature switch reset
button is found behind the louvers on
the rear of the heater. DISCONNECT
THE POWER TO THE HEATER. Use a
non-metallic slim probe; insert carefully
through the louver opening and push
the "red" button to reset OR remove
the louvered rear panel door and push
the "red" reset button; make certain to
re-close the panel before operating the
appliance.
"Red" button
(¾" snap disc manual reset limit
switch shown for clarity.)
Replace the switch.