Overload warning lamp
013557
The warning lamp flickers in red when the tool is
overloaded. If the load reaches some point, the lamp
keeps lighting in red and the tool stops. To restart the
tool, release the trigger and pull the trigger again.
NOTE:
Check what causes the overload when the lamp flickers
or lights up. Change the parameter of the speed
adjusting dial lower, or increase the diameter of the
nozzle.
Switch action
CAUTION:
Before inserting the battery cartridge into the tool,
•
always check to see that the switch trigger
actuates properly and returns to the "OFF"
position when released.
When not operating the tool, push the trigger-lock
•
button from A side to lock the switch trigger in the
OFF position.
B
1
2
013559
To prevent the switch trigger from accidentally pulled,
the trigger-lock button is provided.
To start the tool, push the trigger-lock button from B side
and pull the switch trigger. Tool speed is increased by
increasing pressure on the switch trigger. Release the
switch trigger to stop.
After use, press in the trigger-lock button from A side.
Lighting up the lamp
CAUTION:
Do not look in the light or see the source of light
•
directly.
1. Warning lamp
1
1. Lock lever
2. Switch trigger
A
1
013570
Pull the switch trigger to light up the lamp. The lamp
keeps on lighting while the switch trigger is being pulled.
The lamp goes out approximately 10 seconds after the
switch trigger is released.
NOTE:
Use a dry cloth to wipe the dirt off the lens of lamp.
•
Be careful not to scratch the lens of lamp, or it
may lower the illumination.
When the tool is overheated, the lamp flickers.
•
Cool down the tool fully before operating again.
Drip preventive function
The motor keeps running for a short time even after the
trigger is released. It releases the pressure of the
caulking material and prevents dripping.
ASSEMBLY
CAUTION:
Always be sure that the tool is switched off and the
•
battery cartridge is removed before carrying out
any work on the tool.
Always place the tool on the ground or workbench
•
when carrying out any assembling work. The tool
without being held tight may loose balance and
cause injury.
Installing holder joint
013610
Attach the holder joint firmly along the tool, set the plate,
and fix them with screws tightly.
To remove the holder joint, follow above procedure in
reverse.
6
1. Lamp