Installation • Instalación
Installation • Instalação
wrong • no correcto
incorrect • incorrecto
18
correct • correcto
correct • correcto
english
1. Feed pipe and fitting at least 1"!
(internal dia. > 0.83 inch)
2. No filters in feed line!
3. Slope in feed line > 1 %!
4. Only use ball valves with full open
port!
5. Pressure: min. 12 psig or 18 psig
bar! (check type plate for correct
pressure)
6. Short pressure hose!
7. For each metre of rising slope in the
outlet line, the required minimum
pressure will increase by 1.5 psig.
The rise of the outlet line must not
exceed 17 feet!
8. Collecting line min. 1" with 1%
slope!
9. Always install a venting line!
10. The upper ¾" connection should
only be used as a condensate inlet
in exceptional cases since this could
lead to inflow problems.
Note:
Pressure differences!
Each condensate source must be drained
separately!
In the case of condensate inflow from
the top, the feed line should preferably
be short (internal dia > 18 mm).
In the case of inflow problems, install
venting line.
Note:
Venting line
The BEKOMAT 16 should always be
installed with a venting line when feeding
into the bottom part..