4
th
intensive speed key (**) ("P3" symbol flashes)
is activated by pressing the "P3" key again
PT: TIMER key ("PT" symbol flashes)
PL: LIGHT ON/OFF key ("PL" symbol lights up)
Light Control
•
P0: Motor ON/OFF key ("P0" symbol lights up)
P8: key for reducing motor speed: when the hood
works at first speed it turns the motor off.
P9: key for increasing motor speed: if the hood is off, it
activates first speed ("P0" symbol lights up), by
pressing it for the second time the 2
activated ("P0+P8" symbols light up), by pressing it
for the third time the 3
("P0+P8+P9" symbols light up), by pressing it for
the fourth time intensive speed is activated (**)
("P0+P8" symbols light up and "P9" symbols
flashes)
PT: TIMER key ("PT" symbol flashes)
PL: LIGHT ON/OFF key ("PL" symbol lights up)
Mechanic Control
•
P0: motor OFF key
P1: 1
st
speed key
P2: 2
st
speed key
P3: 3
st
speed key
PL: LIGHT ON/OFF key
(**) Intensive speed: (if available). Intensive speed
lasts for 6 minutes: once elapsed, electronics
automatically resets motor at 3
TIMER: timer performs a 15 minute countdown and
can be activated only when the motor is on.
The 15 minutes timer duration will not change even if
speeds are changed during the countdown.
When the 15 minute time elapses, the hood switches
off.
Metal grease filters cleaning signal
After 30 hours of operation, "PL" key will flash every 2
seconds intermittently and grease filters need to be
washed.
The grease filters pilot lamp reset shall be done only
after having cleaned the filters, by simultaneously
pressing "PT+PL" keys for 4 seconds with the hood
switched off.
Charcoal or long-life filters cleaning signal
After 120 hours of operation, "PL" key will flash every
0,5 seconds intermittently and the filters need to be
replaced or washed depending on the type of filter
used.
The charcoal or long-life filters pilot lamp reset shall be
done only after having cleaned the filters, by
simultaneously pressing "PT+PL" keys for 4 seconds
with the hood switched off.
(fig.18)
nd
speed is
rd
speed is activated
(fig.19)
rd
speed
MAINTENANCE
CAUTION! Disconnect the hood from power supply
before carrying out any cleaning or maintenance
operation,
by
removing
disconnecting the main power switch.
Cleaning
The appliance shall be cleaned quite often, both
internally and externally, using a cloth dampened with
tepid water and a non-abrasive, neutral liquid
detergents.
Metal grease filters
They capture grease particles from cooking fumes and
protect the motor, therefore they can obstruct at
various times depending on the use of the appliance.
These filters can be washed in the dishwasher, with
short washing cycles at low temperature, maximum
every two months in order to prevent fire risk Filters
may change in color after several washings: this will
not entitle users to claim for replacement.
Charcoal filters
They capture odors and purify the air which is then re-
conveyed into the room.
- Charcoal filters are neither washable nor renewable
and shall be replaced every 4 months. Charcoal filters
saturation depends on how much you use your hood.
To replace charcoal filters, open the panel, remove the
metal grease filter and then remove the charcoal
filters.
(fig. 6 - 15)
- Renewable charcoal filters can be washed in the
dishwasher at a maximum temperature of 65°
(complete washing cycle without dishware) or hand-
washed using non-abrasive neutral detergents.
Remove excess water having care not to damage the
filter, place it in the oven for 10 minutes at 100°C in
order to dry it.
Replace the pad every 3 years or every time the cloth is
damaged. (fig. 6 - 16)
Lighting
The hood is equipped with a LED technology-based
lighting system whose main features are high
efficiency, low consumption and very long life-time
under normal use conditions.
Contact the technical assistance service to replace
lighting.
THE MANUFACTURER declines all liabilities for any
damages resulting from incorrect installation or
misuse of this appliance.
13
the
power
cord
(fig. 6)
or