Terminal Block
12V
TAMPER NC
RELAY NC
Jumper Settings
LED
PULSE
LED Indicators
LED 1
LED 2
LED 3
Adjustment of the Vertical Angle
Loosen the fixing screw of the PCB in order to move the PCB up
or down. This enables the user to adjust both the detection angle
and the reach of the device while avoiding detection of small
(domestic) animals.
Heat Detectors
This device is equipped with two heat detectors for motion
detection. DO NOT TOUCH THE HEAT DETECTORS!
V. 02 – 27/04/2020
HAA54
Connect the positive terminal (+) to a power
source of 9-16VDC on the alarm control panel.
Connect the negative terminal (-) to the
grounding point of the control panel.
Connect these terminals to a 24hr N.C.
(Normally Closed) protection zone of the alarm
control panel. The tamper switch contact is
closed if the detector's front cover is in place.
The contact will open and an alarm signal will
instantly be sent to the control panel if the front
cover is removed at any time.
This is the alarm output relay of the detector.
These two terminals should be connected to a
N.C. protection zone of the alarm control panel.
Place the jumper in the "ON"-position to arm all
LEDs or place it in the "OFF"-position to
deactivate all LEDs. Detection is still possible
with the jumper in the "OFF"-position.
Place the pulse count jumper in the "NORMAL"-
position for standard detection in a stable
environment. Place the pulse count jumper in
the "HARSH"-position for double detection within
12 seconds. Pets are ignored in this mode, which
is particularly useful if the device is installed in
an unstable environment.
"ON" upon detection by the upper channel
"ON" upon detection by the lower channel
"ON" when the alarm is activated, flashes during
the warm-up delay
7