Descargar Imprimir esta página

Bradley On-Site S19-921 Manual Del Usuario página 5

Lavador de ojos de alimentación por gravedad
Ocultar thumbs Ver también para On-Site S19-921:

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation
Pedestal
Step 3: Test eyewash unit
1. After completing installation, test the eyewash station for proper
operation by pulling down the tray. Check for proper water
flow and quickly close the tray. Visually inspect the eyewash
unit weekly for cleanliness and proper solution level (per ANSI
Standard Z358.1-2009). When the water level drops below the
15-minute fill line, the tank must be emptied and then refilled. To
refill the eyewash tank, follow the procedures outlined in Step 2
found on page 4.
2. Attach the eyewash inspection tag (supplied) to the eyewash unit.
This tag is to be used for weekly inspection documentation. Hook-
and-loop fasteners are provided to attach the tag to the unit.
3. If the eyewash unit is not working properly, remove it from the
hazard area and contact Bradley Corporation immediately.
Bradley • 215-1546 Rev. M; ECN 12-05-016E
Tank
Cap
Snorkel
Clamp
Latch
Pierce
Drain Hole
8/9/2012
S19-921
5

Publicidad

loading