Paoli Avvitatori DP 196 Manual De Instrucciones página 13

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

OPERATING AND MAINTENANCE MANUAL
HANDLING
L Clockwise rotation (tightening): Slide "T" to
the left the rotation reverse shaft and push
"P" the trigger
(view figure Fig.3-A and
figure
Fig.3-C).
ACCESSORIES ASSEMBLY
When changing accessory, always disconnect
the pressure lines.
Use only accessories suitable for the job.
L "Square drive without hole e with retainer
ring": Insert the accessory "A" in the square
drive of the tool, with an axial pressure
figure
Fig.4-A).
MAINTENANCE
L At regular intervals supply it with the
addition of lubricant
order to keep the appliance efficient and to
extend its service life.
L Clean the supply filter and drain off the
condensation at regular intervals
figure
Fig.1).
L Use only genuine spare parts and authorized
service organizations.
L Do not carry out maintenance with improper
tools, make use of the attached exploded
drawing with the list of spare parts.
L Indicate the parts most subject to wear,
to be dismantled and checked at regular
intervals, as well as a list of malfunctions, if
any, and the corrective action.
SCRAPPING
Separate the components on the basis of the nature of the materials of which they are made .
Translations of the original operating instructions
is Italian.
(view
(view figure
Fig.1), in
(view
L Counter clockwise rotation (loosening):
Slide "T" to the right the rotation reverse
shaft and push "P" the trigger
Fig.3-B and figure
L "Square drive with hole and retainer ring":
Insert the accessory "A" in the square drive
of the tool, with an axial pressure, use
the pin "S" and the ring "R"
Fig.4-B).
L Every three weeks clean the motor by
introducing naphtha (~25cc) through the
air inlet, while keeping the trigger pressed;
then running the wheel gun clockwise and
anticlockwise. After the inside washing,
repeat the previous operation with oil for
air tools (~5cc). These operations must be
performed in a suitably equipped working
environment, complete with extraction
equipment for nebulised particles. Use
personal protective equipment.
L If the tool is left unused for long periods
we recommend putting some oil into the
air inlet and letting it run for a few seconds
before putting it away. In this way the
internal components will remain lubricated.
- The original language of these instructions
(view figure
Fig.3-C).
(view figure
ENGLISH
13

Publicidad

Tabla de contenido
loading

Tabla de contenido