Error code
Description
C - 1
Basic parameter error in flash or RAM - Meter must be replaced
E 1
Temperature range outside [-19.9 °C...199.9 °C] e.g. sensor short-circuit,
sensor break
E 3**
Forward and return sensor reversed
E 4
Hardware error US measurement, e.g. transducer or control defective or short
circuit
E 5
Communication not possible (too frequent read-out)
E - 6**
Flow direction of flow meter incorrect
E 7
No plausible ultrasound receiver signal, e.g. air in the measuring path
E 8
No primary power supply (only with power supply unit); supply via backup
battery
E 9
Battery nearly discharged, design lifetime reached
E A*
Leak: Pipe break detection
E b*
Leak: Energy meter leak detection
E C*
Leak: Leak pulse input 1
E d*
Leak: Leak pulse input 2
* optional ** application dependent