MHTeam DH1-70 Manual De Instrucciones página 6

Calefactores diesel y keroseno
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

6. Instructions for Use
6.1. Start-up
Fill tank with clean fuel. Only use Diesel or Kerosene.
The fuel gauge on top of the tank allows to check fuel level
Connect the power cord plug to a 230 V 50 Hz earthed
electrical supply system.
Earthing is mandatory.
For indirect fired heaters: connect the heater to a
chimney or to an exhaust duct. To get a proper
draught in the chimney the exhaust gas path must
rise. Avoid any elbows and bends in the first part
of the exhaust ducts for at least 3 m.
When complete "start-up" above, the left display window shows "--", the right display window shows ambient
temperature value.
Push the power switch to "on" position, now left display shows the last setting temperature.
If the ambient temperature is lower than setting, after waiting few seconds for pre-ventilation, the heater starts.
If the ambient temperature is higher than setting temperature, push thermostat control button to set desired
temperature, after waiting few seconds for pre-ventilation, the heater starts.
VENTILATION MODE: Simultaneously pressing the setting buttons of the room temperature, the flame goes out
and the device continues to function as a fan.
ABNORMAL OPERATION: in case of malfunction (flame failure, reduced air flow, bad combustion, etc.) the
heater stops, the LOCK-OUT MODE code will be showed on the display window-see troubleshooting.
6.2. Manual reset/restart
If the heater is in lock-out mode, check and remove the cause of lock-out before restarting the heater. To reset, turn
the ON/OFF switch to 0 and then (after few sec) again to I. In case of repeated malfunction, call technical service.
Turning the thermostat control knob will NOT reset the heater.
6.3. Shut-down
Move switch to "OFF" (O) position. The post-ventilation phase will cool down the combustion chamber for 90
seconds. Unplug the unit when not used for a long time.
Never disconnect the heater from mains to stop it while in operation. Always allow the cooling
sequence to be completed, otherwise the residual heat could damage internal components.
Do not cover the heater. Do not block the air inlet and outlet.
The heater outlet is very hot during operation and after use. Do not touch! Use personal protecting
equipment if needed.
Children should be supervised to ensure that they do not play with the appliance.

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Dh1-100Dh2-i-55Dh2-i-85

Tabla de contenido