OIL
Please check the oil level every six months. The oil
capacity is about 0.3L. Restore the fluid level in the
reservoir to 5mm below the top; this must be
done with the forks in the DOWN position.
Use hydraulic oil ISO-VG32 or equivalent.
Oil viscosity should be 30cSt at 104°F (40°C).
HOW TO EXPEL AIR FROM THE PUMP UNIT
Air may enter the unit over time or when the seals are
replaced. To expel the air, lift the control lever to the
For safe operation of the Hand Pallet Truck, please read
all warning signs and instructions here and on the pallet
truck prior to use.
1.
Do not operate the pallet truck unless you are familiar
with it and have been trained and authorized to do so.
2. Do not use the truck on sloping ground.
3. Never place any part of your body in the lifting
mechanism or under the forks or load. Do not carry
passengers.
4. We advise that operators should wear gloves and
safety shoes.
Figure 2
PAGE 2 OF 6
MAINTENANCE
DOWN position and move the handle up and down
several times.
DAILY CHECK AND MAINTENANCE
Daily checks of the pallet truck can limit wear and tear
on the unit. Pay special attention to the wheels, the axles,
the handle, the forks and lift and lower control.
LUBRICATION
Use motor oil or grease to lubricate all movable parts.
SAFETY
5. Do not handle unstable or loosely stacked loads.
6. Do not overload the truck.
7.
Always center loads on the forks, not at the end of the
forks. (See Figure 2)
8. The capacity of the truck assumes an evenly
distributed load with the center of the load being at
the halfway point of the length of the forks.
9. Make sure that length of the forks matches the length
of the pallet load.
10. Lower the forks to lowest height when the truck is not
being used.
A
B
0312 IH-1043