Descargar Imprimir esta página

Publicidad

Enlaces rápidos

INSTALLATION, CARE & USE MANUAL
EZOTL Series Barrier-Free Water Coolers
EZOTL
EZOTL
24
34
9
SEE FIG. 4
23
44
21
Uses HFC-134A refrigerant
Usa refrigerante HFC-134A
Utilise du fluide frigorigéne HFC-134A
EZOTL8*1C, 2C, 3C
Manual de Instalación, Cuidado y Utilización
Manuel d'installation/entretien/utilisation
T M
TM
La Barrera de la serie Liberta Agua Coolers
TM
Coolers d'Eau de Barrière-Libère de feuilleton
43
5
23
46
1
37
15
Page 1
EZODTL*C
33
45
43
47
9
Sensor Eye
Adjustment Screw
FIG. 1
42, 32, 31
38
17, 18
13
16
23
47
46
3
SEE FIG. 3
20
25
23
26
14
27, 28, 29, 30
98397C (Rev. A - 6/08)

Publicidad

loading

Resumen de contenidos para Elkay EZOTL Serie

  • Página 1 EZOTL8*1C, 2C, 3C EZODTL*C INSTALLATION, CARE & USE MANUAL Manual de Instalación, Cuidado y Utilización Manuel d’installation/entretien/utilisation EZOTL Series Barrier-Free Water Coolers EZOTL La Barrera de la serie Liberta Agua Coolers EZOTL Coolers d’Eau de Barrière-Libère de feuilleton 17, 18 Sensor Eye SEE FIG.
  • Página 2 EZOTL8*1C, 2C, 3C EZODTL*C Page 2 98397C (Rev. A - 6/08)
  • Página 3: Instalación Del Enfriador

    EZOTL8*1C, 2C, 3C EZODTL*C HANGER BRACKETS & TRAP INSTALACIÓN DE LOS SOPORTES INSTALLATION DES SUPPORTS FIJADORES Y EL PURGADOR DE SUSPENSION ET DU SIPHON INSTALLATION Retire el soporte fijador que se encuentra 1) Retirez le support de suspension fixé au dos du 1) Remove hanger bracket fastened to back of conectado a la parte posterior del enfriador refroidisseur en retirant une (1) vis.
  • Página 4: Atienda A Instrucciones

    EZOTL8*1C, 2C, 3C EZODTL*C Service Instructions Bubbler Lower and Upper Shroud To access the refrigeration system and plumbing connections, remove four screws from bottom of cooler to remove the lower shroud. To remove the upper shroud for access to the pushbars, regulator, solenoid valve or other components located in the top of the unit, remove lower shroud, disconnect drain, remove four screws from tabs along lower edge of upper shroud, unplug two wires and water tube.
  • Página 5: Limpieza

    EZOTL8*1C, 2C, 3C EZODTL*C SENSOR RANGE ADJUSTMENT: The electronic sensor used in this cooler is factory pre-set for a “visual” range of 36 inches (914 mm). If actual range varies greatly from this or a different setting is desired, follow the range adjustment procedure below: Using a small tip screwdriver, locate range adjustment screw through the small hole between the sensor lenses (See Page 1.) Turn this screw clockwise to increase range and counterclockwise to decrease range (See Fig.
  • Página 6: Descripción

    EZOTL8*1C, 2C, 3C EZODTL*C SENSOR ADAPTER TAB SENSOR OVERLOAD SOLENOID OVERLOAD VALVE SOLENOID VALVE COMPRESSOR COMPRESSOR COLD COLD CONTROL CONTROL MALE TERMINAL ON MALE TERMINAL ON WHITE SHORT LEAD WHITE SHORT LEAD ON POWERCORD ON POWERCORD RELAY RELAY WIRING DIAGRAM - EZO 230v 115V - WIRING DIAGRAM El ESQUEMA que ALAMBRA - EZO 230v 115V - El ESQUEMA que ALAMBRA...
  • Página 7 POUR OBTENIR DES PIÈCES, CONTACTEZ VOTRE DISTRIBUTEUR LOCAL OU COMPOSEZ LE 1.800.323.0620 PRINTED IN U.S.A. IMPRESO EN LOS E.E.U.U. IMPRIMÉ AUX É.-U. ELKAY MANUFACTURING COMPANY • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484 Page 7 98397C (Rev. A - 6/08)

Este manual también es adecuado para:

Ezotl8 1cEzotl8 2cEzotl8 3cEzodtl c