Installation requirements
NOTE
If cabinet has a drawer, a minimum 127 mm (5") depth clearance from the bottom
of cooktop to top of the drawer (or other obstruction) in base cabinet is required.
IMPORTANT:
The junction box must be located where it will allow considerable slack in the
conduit for serviceability.
6 English
Radiant Install_NZ30K7570R_DG68-00825A-03_EN+MES+CFR.indb 6
Make sure the wall coverings, countertop
and cabinets around the cooktop can
withstand heat (up to 194 °F) generated by
cooktop.
Electrical requirements
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge solid copper wire.
Electrically ground cooktop.
Failure to follow these instructions can
result in death, fire, or electrical shock.
If codes permit and a separate ground
wire is used, it is recommended that a
qualified electrical installer determine that
the ground path and the wire gauge are in
accordance with local codes.
Check with a qualified electrical installer if
Label
you are not sure the cooktop is properly
Refer the label on the bottom of the
grounded.
cooktop for power requirements
and model information.
This cooktop must be connected to a grounded metal, permanent wiring system.
Be sure that the electrical connection and wire size are adequate and in
conformance with the National Electrical Code, ANSI/NFPA 70-latest edition or CSA
Standards C22.
1-94, Canadian Electrical Code, Part 1 and C22.2 No. O-M91-latest edition, and all
local codes and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
1/13/2017 3:58:56 PM