44109 (12IN.), 44110 (18IN.), 44112 (24IN.),
44113 (36IN.), 44114 (48IN.)
DIRECT WIRE
LED LIGHT FIXTURE
SAVE THESE INSTRUCTIONS IN A LOCATION CLOSE TO YOUR CABINET
SO YOU CAN REFER TO THEM AT A LATER TIME.
CAUTION: DO NOT USE POWER TOOLS TO SECURE SCREWS, AS
THERE IS A RISK OF STRIPPING THE SCREWS.
DO NOT USE WITH A DIMMING CIRCUIT OR ANY OTHER
ELECTRONICALLY SWITCHED CONTROL.
DO NOT EXCEED THE MAXIMUM CONNECTED UNITS INDICATED ON
THE POWER ADAPTER/LED DRIVER.
PACKAGE CONTENTS
A
A.
Light Fixture x1
B.
M4 x 12mm short mounting
screw x2
INSTALLATION PROCEDURE FOR DIRECT
WIRE LIGHT FIXTURE
Note: For kitchen installations, the recommended mounting for
the dimmable LED light fixture is near the front lip of your under
cabinets as shown in the illustration (see Figure 1). The LEDs
will face the front of the cabinet. This provides the best light
distribution across a countertop.
1. Consult a local licensed electrician or electrical
contractor if you are not sure about the installation.
2. Ensure that electricity is TURNED OFF at the main
circuit breaker or fuse box. DO NOT ATTEMPT TO
INSTALL FIXTURE WITH THE POWER ON.
3. Select a suitable dry mounting location (for use
indoors only). Make sure mounting surface is capable
of supporting the LED light fixture.
4. Remove the lens/diffuser by lightly pulling the rear edge
toward the front and upward. The lens/diffuser should
pop out easily.
5. Remove the cover/housing by unscrewing the screws
located on the top of the cover. Firmly push forward on
the bottom front of the housing to unlatch it from the
catch points. The hardware kit is inside the wiring cavity.
READ IT OR WATCH IT
Read instructions or watch easy-to-follow video.
Scan QR code or visit bit.ly/2x6kvSz
B
C
C.
Strain relief assembly x1
CABINET
COUNTER TOP
6. Ensure that there is adequate space to install the
fixture by using the base as a mounting template.
While the base is held in place, mark location for pilot
holes (see Figure 2).
7. Choose a suitable knock-out location from those provided
on the fixture. Remove the knock-out with a screwdriver
(not included).
8. Remove the nut and lock washer and insert the threaded
end of the strain relief into the selected opening on the
fixture. Secure the strain relief by tightening the nut and
lock washer. The nut and lock washer should be tightened
with a tool such as a pair of pliers (not included) to ensure
the strain relief is properly grounded to the fixture.
9. It is recommended that a pilot hole be drilled in the
mounting surface for wood screws. Pre-drill holes in
the mounting surface with a 1/16in. (1.5mm) drill bit for
softwoods and a 3/32in. (2.4mm) drill bit for hardwoods.
10. Drive the screws into the mounting surface until
approximately 1/8in. (3.1mm) of space remains under the
head of the screw (see Figure 3).
11. Align the keyholes in the fixture with the two screws and
slide into place (see Figure 4).
12. Tighten screws to secure fixture.
13. For ease of installation, the top cover can be hung on the
base, which is already attached to the cabinet, using the
built-in hanging flanges.
14. Install the armored cable to meet electrical codes. Tighten
the two screws on the strain relief connector to secure
the cable.
15. Connect the hot (black) AC supply wire to the hot (black)
wire of the fixture. Secure the connection with the quick
FIGURE 1
connects (see Figure 5). Pull wires to check for tightness.
16. Connect the neutral (white) AC supply wire to the neutral
(white) wire of the fixture. Secure the connection with
the wire quick connects (see Figure 5). Pull wires to check
for tightness.
17. Connect the ground (green or bare copper) AC supply wire
to the green or bare copper ground (green or bare copper)
wire of the fixture. Secure the connection with the wire
quick connects (see Figure 5). Pull wires to check for
tightness. If your electrical system contains no grounding
wire, you should consult a qualified electrician before
proceeding with the installation.
18. Ensure that no bare wires are exposed after making the
electrical connections.
19. Arrange the wires inside the fixture and reattach the
cover/housing by reversing the removal instructions.
Ensure all the wires and connections are sealed properly
inside the fixture without "pinching" any wires. Ensure the
top cover screws and washers are secure.
20. Reinsert lens.
21. Turn on the electricity at the circuit breaker or fuse box.
FIGURE 2
1/16IN. (1.58MM)
FIGURE 3
1/8IN.
3.1MM
FIGURE 4
INSERT
SLIDE
FIGURE 5

Publicidad

loading

Resumen de contenidos para Honeywell 44109

  • Página 1 READ IT OR WATCH IT Read instructions or watch easy-to-follow video. Scan QR code or visit bit.ly/2x6kvSz 44109 (12IN.), 44110 (18IN.), 44112 (24IN.), 44113 (36IN.), 44114 (48IN.) DIRECT WIRE LED LIGHT FIXTURE FIGURE 2 6. Ensure that there is adequate space to install the SAVE THESE INSTRUCTIONS IN A LOCATION CLOSE TO YOUR CABINET fixture by using the base as a mounting template.
  • Página 2 FCC/IC - EN Suppliers Declaration of Conformity | Model #: 44109, 44110, 44112, 44113, 44114 | Jasco Products Co., 10 E. Memorial Rd., Oklahoma City, OK 73114, www.byjasco.com This device complies with Part 15 of the FCC and Industry Canada license-exempt RSS standards.
  • Página 3 44109 (12IN.), 44110 (18IN.), 44112 (24IN.), 44113 (36IN.), 44114 (48IN.) CONEXIÓN DIRECTA ACCESORIO DE LUZ LED FIGURA 2 6. Asegúrese de que haya suficiente lugar para instalar el GUARDE ESTAS INSTRUCCIONES EN UN LUGAR CERCANO A SU aparato utilizando la base como plantilla de instalación.
  • Página 4 (PDF), entre otros, visite www.byjasco.com/support FCC/IC Declaración de conformidad del proveedor | Modelo #: 44109, 44110, 44112, 44113, 44114 | Jasco Products Co., 10 E. Memorial Rd., Oklahoma City, OK 73114, www.byjasco.com Este dispositivo cumple con las especificaciones del apartado 15 de las normas de la FCC y con las especificaciones de las normas radioeléctricas (RSS) del Ministerio de Industria...

Este manual también es adecuado para:

44110441124411344114