Sulion RODAN Manual Del Usuario página 6

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1
people, can damage the blades, and can offset the balance of the unit, causing vibrations and wobbling.
9. After installing the fan, ensure that all fastenings are secure and tightened in order to avoid any noise caused by loose
elements.
10. Due to the fan's movement, certain fastenings may become loose. Check all fastenings twice per year at a minimum in
order to ensure that they are sufficiently tight. If necessary, they must be retightened.
11. If the power cord is damaged, it must be replaced by the manufacturer, its after-sales service or similar qualified person-
nel in order to avoid any malfunction.
12. The light source of this luminaire must only be replaced by the manufacturer, its technical service or a qualified person.
Note: The important warnings and instructions indicated in this manual are not guaranteed to cover all possible conditions
and situations that may occur. It must be understood that common sense, precaution, and care are factors that cannot be
included in all products. These factors can and must only be provided by the user who maintains and enjoys this fan.
Environmental protection
Do not throw away electrical products together with household waste. We ask you to recycle the packaging at the
collection points provided for this purpose. Contact local authorities or your provider for recycling advice. Thank you
for recycling at the collection points provided for this manual.
Device technical spectifications
Nominal voltage and frequency
Light wattage
Luminous flux
Light color temperature
Nº of light ON/OFF cycles
Nº of hours of light lifespan
Protection category
Protection index
Word temperature
Dimmable/Not dimmable
Maximun ceiling slope on which it can be installed
Light angle
Light Ra
Weight
Speed
Fan power (W)
Fan RPM
Fan airflow (m³/min)
Noise level (dB)
Preparing for installation
Note: The estimated installation time is 120 minutes. This product can only be installed by a certified electrician Carefully
separate the fan's parts, avoiding the use of cutters or blades that could scratch any part of it.
10
220-240V~AC 50/60Hz
24W
2000lm
3000/4500/6000K
10000
30000h
Class I
IP20
0
45ºC
No dimable
15º
170º
80
4,8kg
1
2
3
4
5
6
3
5,6
8,2
12
16,5
24
110
123
191
225
252
285
46,6
60,8
78,3
96,6 112,5 133,3
15
20
25
30
35
40
Remote control
FAN
Turn on / Turn off
OFF
Turn on / turn off light /
Change color temperature of the light.
2H
Natural wind (Speed cycle 1-6
progressive)
Self-temperature sensor
26ºC
26ºC - 19ºC Speed= 3
3 3
4 4
<19ºC
FAN
Note: Press another button except
2 2
5 5
OFF
to exit the function.
6 6
1 1
Timer 2h
2H
Change sense of rotation
1
Speed 1
2
Speed 2
3
Speed 3
Speed 4
4
Speed 5
5
Speed 6
6
Syncing the receiver and the remote control for fan operation
If the receiver and transmitter of this fan are properly synchronized, the fan will work. During synchronization the receiver
recognizes the signal from the transmitter, this is called the learning process.
Make sure the fan is disconnected. This is essential for the synchronization process.
Unless the synchronization process has been successful, the fan will work partially or will not work. By default, all fans have
been preconfigured at the factory and should be functional once the installation is completed and the fan is turned on.
If the remote control does not work after installation or during use, synchronization can be performed as indicated below. Note
in any case that there could be other reasons why your fan or remote control does not work:
Make sure all connections are correctly made.
Make sure that the remote control contains batteries.
Make sure that all switches (main and isolation) are on.
Instructions for synchronizing the receiver and the remote control
The control of this fan does not require synchronization with the recelver, the control is already factory-linked with its receiver;
Universal mode and Unit mode:
- Unit Mode:
This type of synchronization allows you to control two or more nearby fans independently, each with its remote control.
Synchronization:
The control of this fan does not require synchronization with the receiver, the control is already factory-linked with its receiver
- Universal Mode:
This type of synchronization allows you to control one or more nearby fans with the same remote control.
Synchronization:
1.- On and Off the Switch for 8 times. Then you will heard "beep beep beep".
2.- Within 2 seconds press
for 1-2 seconds. Then will heard "beep beep", setting completed.
It is not possible for a controller to forget a fan once it has been linked, if you want a fan to leave
to obey a command, another one must be linked to "overwrite it".
Remote control safety functions
Blocking protection
The remote receiver includes a function that automatically blocks motor operation, cutting current to the motor 30 seconds
after detecting an obstruction in front of the fan that prevents normal operation. When this happens, you must remove the
obstacles blocking the fan. Then, press the off button on the remote control to reset the receiver. Now you can continue to
use the fan normally.
Speed= 6
Speed=1
FAN
, 2h or
OFF
11

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Crixus072133072134