Environmental Specifications - TDK-Lambda NV700 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 9
NV700 Handbook

Environmental Specifications:

Description
Use
Temperature
Humidity
Altitude
Pressure
Orientation
Material Group
Pollution Degree
Overvoltage Category
Description
Class
Weight
IP Rating
* - 3000m for 60601-1 Edition 2 and 61010-1 Edition 3 standards.
Level of Insulation:
Primary mains circuits to earth: 2.25 – 2.35Kvdc.
Primary mains circuits to secondary and earth: 4.25 - 4.35kVDC**.
Primary mains circuits to transformer core: 4.25 - 4.35kVDC**.
Outputs to each other and to earth are isolated to 200VDC except CM modules which are 730 – 760Vdc to earth.
** This test is not possible with Y capacitors fitted to the unit as damage to these capacitors may occur.
Safety Approvals:
UL60950-1 and CSA22.2 No.60950-1 - UL Recognised. C-UL for Canada.
IEC / EN60950-1 - CE mark.
IEC/EN60950-1, IEC/EN 61010-1 and IEC/EN60601-1 - CB Report and Certificate.
CE marking when applied to any NV700 product indicates compliance with the Low Voltage Directive in that it
complies with EN60950-1 and with the ROHS Directive. UL/CSA 61010-1 : UL + C-UL approval
UL/CSA 60601-1 : UL + C-UL approval
Fusing: Internal fuse (F1): F16AH, 250V fuse 6.3x32 mm.
Symbols:
AC
EARTH
If the earth terminal of the NV700 PSU is connected to the main incoming earth conductor of the end equipment, the
installer must cover the earth symbol with a label bearing the earth symbol of IEC60417-5019.
Note: All output voltages/variants may not be available as standard units, refer to datasheet for standard
product range. These (and other variants) may be available as non-standard or custom units, please contact
our sales team for details.
Operation
Indoor
0°C - +65°C (derating above 45°C or 50°C – See
Cooling Options)
5 - 95% RH, non-condensing
-200m - 5000m*
78kPa - 106kPa
Horizontal with chassis lowest, on either
side or vertical with the airflow upwards.
Operation
N – Neutral
IIIb
2
II
I
1 Kg (Dependent on configuration)
IPX0
L – Live
Page 14 of 30
Storage
-
-40°C - +70°C
5 - 95% RH, non-condensing
-200m - 5000m
54kPa - 106kPa
All
Storage
17187 issue 19, October 2018

Publicidad

Tabla de contenido
loading

Tabla de contenido