Installing Lp Gas Tank; Inserting Lp Gas Tank; Securing Lp Gas Tank; Connecting Lp Gas Tank - Backyard Grill GBC1429WRS Manual Del Usuario

Parilla de gas propano para exteriores
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Recipes
BlueRhino.com/recipes

Installing LP Gas Tank

To operate, you will need one precision-filled standard grill LP gas
tank with external valve threads.
W CAUTION: LP gas tank must be properly
disconnected and removed prior to moving this
grill.

Inserting LP Gas Tank

Place precision-filled LP gas tank upright into the notches in the right cart frame so the tank
valve is facing the gas line connection.

Securing LP Gas Tank

Secure tank by sliding the tank retainer wire over shoulder of LP gas tank.

Connecting LP Gas Tank

1.
Before connecting, be sure there is no debris caught
in the head of the LP gas tank, head of the regulator
valve or in the head of the burner or burner ports.
2.
Connect regulator/hose assembly to tank by turning
knob clockwise until it stops.

Disconnecting LP Gas Tank

1.
Before disconnecting, make sure the LP gas tank valve
is "CLOSED."
2.
Disconnect regulator/hose assembly from LP gas tank
by turning knob counterclockwise until it is loose.
W CAUTION: LP gas tank must be properly
disconnected and removed prior to
moving this grill.
3.
Place the protective cap cover on the LP tank and
store the tank outdoors in a well ventilated area out of direct sunlight.
Available at:
Need help? 1.800.762.1142
Do not return to place of purchase.
20 lb
9 Kg
12.2 in. / 31 cm
Replacement Parts
parts.BlueRhino.com /
1.800.762.1142

Operating Instructions

Checking for Leaks

Burner Connections
1.
Make sure the regulator hose and valve
connections are securely fastened to the burner
and the tank.
2.
Visually check the connection between the
burner/venturi tube and orifice.
3.
Make sure the burner/venturi tube fits over the
orifice.
W WARNING: Failure to inspect this
connection or follow these instructions
could cause a fire or an explosion
which can cause death, serious bodily
injury or damage to property.
4.
Please refer to diagram for proper installation
(Figures 1 and 2).
5.
If the burner/venturi tube does not rest flush to the
orifice, as shown, please contact 1.800.762.1142
for assistance.
Tank/Gas Line Connection
1.
Make 2-3 oz. of leak detection solution by mixing
one part liquid dishwashing soap with three parts
water.
2.
Make sure control knobs are in the " OFF"
position (Figure 3).
3.
Connect LP gas tank per "Installing LP Gas Tank"
section.
4.
Turn LP gas tank valve to "OPEN."
5.
Spoon several drops of solution, or use a squirt
bottle, at all "X" locations (Figures 1, 2 and 4).
a. If any bubbles appear, turn LP gas tank valve to
"CLOSED," reconnect and re-test.
b. If you continue to see bubbles after several
attempts, turn LP gas tank valve to "CLOSED"
and disconnect LP gas tank, per "Disconnecting
LP Gas Tank" section. Contact 1.800.762.1142
for assistance.
c. If no bubbles appear after one minute, turn
LP gas tank valve to "CLOSED," wipe away
solution and proceed.

Operating Main Burners

First Use
1.
Make sure all labels, packaging and protective
films have been removed from the grill.
2.
Remove manufacturing oils before cooking on this
grill for the first time by operating the grill for at
least 15 minutes on (HIGH) with the lid closed.
This will "heat clean" the internal parts and
dissipate odors.
Lighting
W CAUTION: Keep outdoor gas cooking
appliance area clear and free from combustible materials, gasoline
and other flammable vapors and liquids.
W CAUTION: Do NOT obstruct the flow of combustion and ventilation air.
W CAUTION: Check and clean burner/venturi tubes for insects and insect
nests. A clogged tube can lead to a fire.
W CAUTION: Attempting to light the burner with the lid closed may cause
an explosion.
1.
Open lid.
2.
Check for obstructions of airflow to the burners. Spiders, insects and webs can clog the
burner/venturi tube. A clogged burner tube can lead to a fire.
3.
All control knobs must be in the " OFF" position (Figure 3).
4.
Connect LP gas tank per "Installing LP Gas Tank" section.
5.
Turn LP gas tank valve to "OPEN."
6.
Push and turn any control knob to (HIGH). The burner should light. If it does not, repeat
up to three times.
7.
If ignition does not occur in 5 seconds, turn burner control knob " OFF," wait 5 minutes,
and repeat lighting procedure.
9
Figure 1: Main Burners
Burner/
Venturi Tube
LP Gas
Connection
LP Gas
Valve with
Orifice
Figure 2: Side Burner
Valve Soft Pipe
LP Gas
Connection
Connection
LP Gas
Burner/
Valve with
Venturi
Orifice
Tube
Figure 3
OFF
APAGADO
Figure 4
X
X
X
X
X

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido