Dandy Designer DER244BSS Manual De Propietario página 21

Estufa eléctrica compacta
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

E. Insert the wire tips (insulation stripped ⅝") into the bottom terminal block openings. Be certain the white wire is in the center. On certain models, the
wire must be inserted through an opening in the ground strap. Securely tighten each screw onto each wire (35 to 50 in-lbs).
F. Reinstall terminal block cover.
NOTE: For conduit wires using copper wires, the allowable gauge of the individual wires is 6-8 AWG.
NOTE: Aluminum building wire may be used but it must be rated for the correct amperage and voltage. For conduit wires using aluminum wires, the allowable
gauge of the individual wires is 4-8 AWG.
Before–Power Cord and Conduit
Terminal
block
Ground
strap
st
Neutral
terminal
ANTI-TIP BRACKET INSTALLATION INSTRUCTIONS
To reduce the RISK OF TIPPING the range, the range must be secured by a properly installed ANTI-TIP BRACKET.
Secure the bracket with the screws provided. See installation instructions for complete details before attempting to install.
NOTE: The installation of the ANTI-TIP bracket must meet all local codes for securing the appliance.
STEP 1 LOCATE THE BRACKET
IMPORTANT
A
Place the bracket on the fl oor with the back edge against
the rear wall. If the range does not reach the rear wall,
align the back edge of the bracket with the rear panel of
the range in its fi nal location.
IMPORTANT
If the bracket does not touch the rear wall, you MUST
screw the bracket to the FLOOR as described in Step 2.
B
Position the side of the bracket against the right cabinet. If
there is no adjacent cabinet, align the edge of the bracket
with the right side panel of the range in its fi nal location. If
the countertop overhangs the cabinet, offset the bracket
from the cabinet by the amount of the overhang.
C
Mark the location for the pair of holes to be used (see illustration above).
NOTE: For FLOOR installation use Loc. A. For REAR WALL installation use Loc. B.
INSTALLATION INSTRUCTIONS
Ground strap
Terminal
block
or
Red or
Black
A child or adult can tip the range and be killed.
Install the anti-tip bracket to the wall or fl oor.
Engage the range to the anti-tip bracket by sliding the range back so the anti-tip
arm slides under the anti-tip bracket.
Re-engage the anti-tip bracket if the range is moved.
Failure to do so can result in death or serious burns to children and adults.
Determine the fi nal location of the range before attempting to install the bracket.
After–Power Cord
Neutral
terminal
Ground plate
(grounding to
range)
White
Red or
Ground
Black
screw
Green
or Bare
WARNING
Tip-Over Hazard
Rear Wall
Two screws must enter floor
or wall at Loc. A or B.
19
After–Conduit
Terminal
block
Wire
tips
Red or
White
Ground
Loc. B
Loc. A
Adjacent cabinet or
final location of right
range side panel.
Ground plate
(grounding to
range)
Red or
Black
Green

Publicidad

Tabla de contenido
loading

Tabla de contenido