TM12-1104-LG1
08/25/2017
mPro400GC-I global controller
Tool Cables
Cable Length
18EAE series
Feet
Non European Union Cables - Air-LB Connector
301866-XXX *
3 - 49
301904-XXX *
3 - 49
301903-XXX *
3 - 49
301877-XXX
3 - 66
European Union Cables - Air-LB Connector
961259-XXX **
3 - 66
961250-XXX **
3 - 66
961251-XXX **
3 - 66
961252-XXX **
3 - 66
961249-XXX **
3 - 66
* Note: 3 ft. and 6 ft. (1M and 2M) cables must be used with
301877 Extension Cable.
** Note: 20M length does not require a transformer.
(1) Standard Durability
(2) High Durability
m-Pro-400GC-I
Series
Tool Cable
5
Initial operation:
Putting into use
Danger of hands being crushed.
→ Always use a reaction bar applications in
restricted space and torques over 50 ft.-
lbs. (68 Nm).
Application
Spindle Rotation
EN
Meters
Description
1 - 15 Tool Cable (1)
1 - 15 Swivel Cable: Inline (1)
1 - 15 Swivel Cable: Right Angle (1)
1 - 20 Extension Cable
1 - 20 Tool Cable (1)
1 - 20 Tool Cable (2)
1 - 20 Swivel Cable: Inline (2)
1 - 20 Swivel Cable: Right Angle (2)
1 - 20 Extension Cable
18EAE Models
Torque
Reaction
EN
Cable Length
18EA series
Feet
Non European Union Cables - Matrix Connector
542778-XXX *
3 - 49
544056-XXX *
3 - 49
544055-XXX *
3 - 49
542779-XXX
3 - 66
European Union Cables - Matrix Connector
------------
------
------------
------
------------
------
------------
------
------------
------
* Note: 3 ft. and 6 ft. (1M and 2M) cables must be used with
542779 Extension Cable.
(1) Standard Durability
Tool Cable
18EA Right Angle Nutrunner Shown
Performing a fastener rundown
The 18E series nutrunners have been configured by Apex
Tool Group. A setting for your specfic fastener joint must
only be made with the nutrunner controller by qualified
personnel
1
, The initial operation can vary depending on the
type and programming of the nutrunner controller. Refer to
the nutrunner controller Programming Manual.
→ Make sure the tool cable is securely attached to the tool
and controller.
→ Make sure the controller is powered on and properly
programmed (refer to the controller manuals).
→ Make sure the reverse mechanism is in the correct
position.
→ Place the socket or bit on the application and depress the
switch actuator to start the rundown.
→ When the nutrunner shuts off, release the switch actuator.
→ Remove the nutrunner from the application.
-------------------------------------------------------------------------
1. Qualified personnel are those who can recognize possible
hazards and institute the appropriate safety measures due to their
professional training, knowl- edge, and experience as well as their
understanding of the relevant conditions pertaining to the work to
be done. Qualified personnel must observe the rules
Page 10
EN
Meters
Description
1 - 15 Tool Cable (1)
1 - 15 Swivel Cable: Inline (1)
1 - 15 Swivel Cable: Right Angle (1)
1 - 20 Extension Cable
------
------
------
------
------
------
------
------
------
------