DETERMINING THE MAXIMUM FILL LEVEL WHEN USING A VESSEL WITHOUT A MAXIMUM
FILL LINE:
1. Place your food into the basket.
2. Place the basket and food into the empty cooking vessel.
3. Fill the vessel with water just until the food is completely submerged. There must be a minimum
of 3 inches (8 cm) between the water level and the top of the vessel.
4. Remove the food from the cooking vessel and either mark the water level on the side of the
cooking vessel or measure the amount of water in the vessel.
5. This is the amount of cooking oil the vessel is to be filled with to cook your food.
6. Remove the water and completely dry the cooking vessel and your food.
PROBLEM
Burner will not light.
Burner does not stay lit.
Water does not reach desired
cooking temperature.
lococookers.com

TROUBLESHOOTING

POSSIBLE CAUSE
Bad connection between the
regulator and LP tank.
The LP tank is empty.
Excessive wind conditions.
The LP tank is empty.
Regulator control knob is not
fully opened.
Overfill Protection Device (OPD)
on LP tank has been activated/
tripped.
Faulty or obstructed regulator
hose.
SOLUTION
Make sure the regulator
coupling nut is fully tightened on
the LP tank valve.
Refill LP tank at an authorized
dealer or purchase new filled LP
tank.
When appliance is cool, move
appliance to different location
where high wind is not a factor.
Relight burner.
Refill LP tank at an authorized
dealer or purchase new filled LP
tank.
Fully open regulator control
knob by rotating it in a clockwise
direction.
To reset the Overfill Protection
Device, turn the regulator
control knob and the LP tank
valve OFF. Disconnect the
regulator from the LP tank
and wait at least one minute.
Reconnect the regulator to the
LP tank and fully open LP tank
valve.
Contact customer service for
replacement regulator/hose
assembly.