Check for misalignment and seizure of moving
parts, breakage of parts and any other conditions
that may affect its operation.
Have damaged guards or other defective parts
repaired or replaced as instructed. Do not use
the tool if the switch is defective. Have the switch
replaced by an authorized D
20 Have your tool repaired by an authorized
D
WALT repair agent
E
This Power Tool is in accordance with the
relevant safety regulations. To avoid danger,
electric appliances must only be repaired by
qualified technicians.
Package contents
The package contains:
1 Percussion drill
1 Side handle
1 Depth gauge
1 Chuck key (D21710/D21716)
1 Kitbox (K-models only)
1 Instruction manual
1 Exploded drawing
• Check for damage to the tool, parts or accessories
which may have occurred during transport.
• Take the time to thoroughly read and understand
this manual prior to operation.
Description (fig. A)
1 Variable speed switch
2 Lock-on button
3 Forward/reverse slider
4 Mode selector
5 Ventilation slots
6 Side handle
7 Depth adjustment rod
8 Keyed chuck (D21710/D21716)
8 Keyless chuck (D21711/D21717)
9 Sleeve
10 Chuck key
Electrical safety
The electric motor has been designed for one
voltage only. Always check that the power supply
corresponds to the voltage on the rating plate.
WALT repair agent.
E
Your D
WALT tool is double insulated in
E
accordance with EN 50144; therefore no
earth wire is required.
Mains plug replacement
(U.K. & Ireland only)
• Should your mains plug need replacing and you
are competent to do this, proceed as instructed
below. If you are in doubt, contact an authorized
D
WALT repair agent or a qualified electrician.
E
• Disconnect the plug from the supply.
• Cut off the plug and dispose of it safely; a plug
with bared copper conductors is dangerous if
engaged in a live socket outlet.
• Only fit 13 Amperes BS1363A approved plugs
fitted with the correctly rated fuse (1).
• The cable wire colours, or a letter, will be marked
at the connection points of most good quality
plugs. Attach the wires to their respective points
in the plug (see below). Brown is for Live (L) (2)
and Blue is for Neutral (N) (4).
• Before replacing the top cover of the mains plug
ensure that the cable restraint (3) is holding the
outer sheath of the cable firmly and that the two
leads are correctly fixed at the terminal screws.
Never use a light socket.
Never connect the live (L) or neutral (N)
wires to the earth pin marked E or
For 115 V units with a power rating exceeding 1500 W,
we recommend to fit a plug to BS4343 standard.
Using an extension cable
If an extension cable is required, use an approved
extension cable suitable for the power input of this
tool (see technical data). The minimum conductor
2
size is 1.5 mm
. When using a cable reel, always
unwind the cable completely.
Also refer to the table below.
E N G L I S H
.
19