Helo Steam Pro Instalación Y Manual De Uso página 40

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 73
Instructions for Use and Installation Helo Steam Pro
NOTE: Controlling the lights in the steam room with the circuit board is is only possible with resistive loads
(incandescent light bulbs). The circuit board relay cannot withstand capacitive loads (switched-mode power supply
units). If the lighting fixtures in the sauna have transformers, for example LED or halogen lamps, the steam generator
circuit board's relay control must be fitted with a separate relay or contactor for controlling the lights.
Steam generator resistors
Output
kW
9.5
12
14
16
Selecting the steam generator output for the steam room
You can estimate the power requirement using the formula below.
Volume (m3) x K1 x K2 = Power requirement (kw)
Mechanical ventilation
No ventilation
Acrylic wall
Light wall board + tile
Heavy wall: stone, concrete + tile
Very heavy wall: stone, concrete + tile
In heavy-built steam rooms, we recommended using e.g. an electric heating cable for warming the seats, walls and
floors.
Output
Light structure,
acrylic, tem-
pered glass
kW
No ventilation
9.5
9–17 m³
12.0
12–24 m³
14.0
18–30 m³
16.0
23–35 m³
Table for selecting a steam generator based on the steam room volume and wall materials.
1
5250W / SEPD 116
4250W / SEPD 119
5250W / SEPD 116
5250W / SEPD 116
Light board
wall
+ tile
Air condi-
No ventila-
tioned
tion
9–13 m³
9–14 m³
11–18 m³
11–20 m³
14–22 m³
14–24 m³
17–25 m³
17–27 m³
Resistor 230V
2
3500W / SEPD 115
3500W / SEPD 115
3500W / SEPD 115
5250W / SEPD 116
K1 = 0.75
K1 = 0.52
K2 = 1.00
K2 = 1.25
K2 = 1.50
K2 = 2.00
Heavy
wall,
concrete,
stone
Air condi-
No ventila-
tioned
tion
8 – 13 m³
7–11 m
9–16 m³
9–16 m³
12–18 m³
11–17 m³
14–20 m³
12–18 m³
3
5250W / SEPD 116
4250W / SEPD 119
5250W / SEPD 116
5250W / SEPD 116
Steam
kg / h
Air condi-
tioned
6–9 m
13
8–12 m³
16
10–14 m³
19
12–16 m³
21
11

Publicidad

Tabla de contenido
loading