INTRODUCING JBC TECHNOLOGY
The exclusive JBC heating system achieves an
exceptional thermal recovery, which increases
productivity, quality, reduces cost of ownership
and ensures fast return on investment.
Unequalled thermal response
An excellent soldering tool features instant thermal
response conceived by a high power/mass ratio.
A high power/mass ratio is being used to maintain
the tip's temperature as close as possible to the
one selected on the control unit, even when the
thermal load is significant. This is the formula
needed to perform high quality solderjoints and
avoid cold ones, protect the PCB that is being
soldered and increase productivity.
INTELLIGENT HEAT MANAGEMENT
The only time that a soldering tool should be at
working temperature is when it is actually being
used. JBC stations identify if and how a tool is
being used and depending on this switches the
tool to one of the following modes with their
respective temperatures:
Work mode: selected working temperature i.e.
350°C.
Sleep mode: during short periods of inactivity
the tool's temperature is being lowered to an
intermediate temperature i.e. 220°C.
Hibernation mode: During larger periods of
inactivity i.e. 30 minutes, the tool's power is being
cut off and it cools down to room temperature.
The advantages of this heat management are
significantly increased catridge lifespan and
substantial energy savings which ensures low
cost of ownership.
JBC Tools save money by managing Heat
efficiently saving energy, time and improving
processes.
If you would like to change the SLEEP and
HIBERNATION parameters, as any other
function, see page 11.
Technical specifications
- Temperature selection from 90 to 450°C or 190
to 840°F (±5%).
- Power: 75W.
- Safety transformer, mains separator and double
isolation, with integrated temperature protection
fuse.
- DI 2870 230V control unit
Input: 230V 50Hz. Output: 24V.
- DI 2870 120V control unit
Input: 120V 60Hz. Output: 24V.
- DI 2870 100V control unit
Input: 100V±10% 50/60Hz. Output: 24V.
- Total weight of unit: 2,5Kg (6,25lbs).
- ESD protected housing "skin effect".
Typical surface resistance: 10
- Complies with CE standards on electrical safety,
electromagnetic compatibility and antistatic
protection.
- RoHS compliant.
- Equipotential connector and the tool tip are
connected to station mains ground supply for ESD
protection.
This product should not be thrown in the
garbage.
You will find all the information about control unit
DI 2870 in the following link:
http://www.jbc.es/english/catalog
JBC reserves the right to make technical changes without prior
notification.
2
ENGLISH
Ref. 2870216
Ref. 2870116
Ref. 2870016
5
-10
11
Ohms/square.

Publicidad

loading