Descargar Imprimir esta página

Ariston Thermo SGA X 120 EE Instrucciones Para El Uso Y La Manutención página 35

Acumuladores de agua caliente a gas

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 74
CHECKING THE SUPPLY PRESSURE
The gas supply pressure measured at
the pressure fi tting 11 (fi g.5), using a pres-
sure gauge and expressed in mbar.
ADJUSTING THE PILOT FLAME
(EUROSIT valve)
Adjust by acting on screw 11 (fi g.5).
The pilot fl ame is correctly adjusted
when its length is approximately 2-3 cm
and the fl ame touches the upper part of
the thermocouple.
Methane (G20)
LPG
SAFETY DEVICES
To guarantee the correct functionality of
the appliance, this is equipped with the
following safety devices:
- Thermocouple fl ame control
it interrupts the fl ow of gas in case of
no pilot fl ame. The repetitive, not oc-
casional, intervention of this safety de-
vice, indicates an incorrect functioning
of the appliance for which the inter-
vention of qualifi ed staff is necessary.
- Overtemperature thermostat
acts with the same methods of the
thermocouple in case the water tem-
perature exceeds 90°C; in this case,
the appliance cannot be re-ignited un-
til the hot water has been drained.
However, the intervention of qualifi ed
staff is necessary for the removal of
the defect before re-ignition of the ap-
pliance.
Butane (G30)
Propane (G31)
5
13
12
11
GAS SUPPLY PRESSURE
20 mbar
28 ÷ 30 mbar
37 mbar
GB
14
35

Publicidad

loading