►2.3. Check for any damage during transport.
If the heater appears damaged in any way,
please inform your vendor promptly.
►►3. FUEL
!
WARNING: The heater only runs on
DIESEL or KEROSENE fuel.
To avoid fire or explosion, use only diesel or
kerosene fuel. Do not use gasoline, naphtha,
paint thinners, alcohol or any other combustible
liquids.
For low-temperature operation, use antifreeze
supplements.
►►4. OPERATING PRINCIPLE
See Fig. 2
Airflow
is
necessary
combustion, it is supplied by the internal burner
fan. The air enters the burner funnel and gets
mixed with a high-pressure fuel jet. The fuel
flow is secured by an electrical pump, which
sucks the fuel away from the tank and moves it
to the nozzle under high pressure.
►►5. OPERATION
!
WARNING:
"SAFETY CONSIDERATIONS" carefully
before turning the heater on.
!
IMPORTANT: After the first time the
heater does not switch on, make sure
there is fuel in the tank, make sure the
fuel filter is clean and make sure that
the heater is positioned on a flat, stable
surface.
!
IMPORTANT: This is a target infrared
heater. Infrared heats bodies and not the
air.
►►5.1. RUNNING THE HEATER:
►5.1.1. Observe all safety instructions at all
times.
►5.1.2. Check if fuel is present in the tank.
►5.1.3. Close the fuel tank filler plug.
►5.1.4. Plug the feeder cable into the socket
(CHECK THE VOLTAGE IN "TECHNICAL
DATA SHEET").
►5.1.5. Turn the "ON/OFF" switch "ON" (|) (C
Fig. 3). The heater should be online in a few
seconds. If it is not, please refer to the section
to
ensure
proper
Read
the
section
"PROBLEM IDENTIFICATION" (Paragraph
10).
NOTE: IN THE EVENT OF HEATER BEING
TURNED OFF DUE TO RUNNING OUT OF
FUEL, TURN THE HEATER OFF, REFUEL
AND TURN IT BACK ON (SEE PARA. 5.1.).
►►5.2. TURNING THE HEATER OFF:
!
WARNING: DO NOT CUT THE POWER
OR DISCONNECT THE FEEDER CABLE
BEFORE THE HEATER COOLS DOWN
COMPLETELY (ab. 5 minutes).
►5.2.1. Turn the "ON/OFF" switch "OFF" (0)
(A Fig. 3).
►►5.3. ROOM THERMOSTAT
CONNECTION (optional):
Remove the plug connected to the appliance
and connect the room thermostat (optional) (C
Fig. 3).
►►6. CLEANING THE FUEL FILTER
See Fig. 4
DEPENDING ON THE QUALITY OF FUEL
USED, IT MAY BE NECESSARY TO CLEAN
THE FUEL FILTER.
►6.1. Remove the plug on the fuel tank (A Fig.
4).
►6.2. Remove the filter from the tank.
►6.3. Unscrew the cap (B Fig. 4).
►6.4. Remove the filter (C Fig. 4).
►6.6. Clean the filter using clean fuel, do not
damage the filter.
►6.6. Replace the filter inside the tank.
►►7. MAINTENANCE AND
TRANSPORTATION
TO ENSURE THE BEST MAINTENANCE
AND/OR TRANSPORTATION PROCEDURE,
PLEASE
OBSERVE
PROCEDURE:
►7.1. Empty the fuel tank.
►7.2. If remainders are still present, pour in
clean fuel and empty it again.
►7.3. Close the tank filler plug, dispose of the
fuel as per the applicable regulations.
►7.4. To ensure proper heater maintenance,
keep it leveled to prevent fuel leaks, keep
it in a dry place and protect from getting
damaged.