a)
Mark the position for the rawl plug drill holes taking the minimum spacing (distance
between the drillings = 250mm) into consideraton, and insert the rawl plugs (Fig. 2)
Assembly the screws. Hook in the radiant heater
by pushing it to the right side into the arrester.
After that you have to move the device towards
the bottom and to fasten the screws.
b)
Setting the radiant heater's angle:
The radiant heater's angle is infi nitely variable.
Simply tilt it to the desired position (Fig. 3)
Caution:
DO NOT TOUCH the radiant heater during and shortly after use! (HEAT RADIATION)
Plug the heater into the socket-
the heater is now ready for use
Caution: Do not place the power cord over the radiant heater!
• The local electrical regulations (EVU) must be complied with when installing the heater in
bathrooms and shower rooms. The heater must be positioned so that the pull switch
cannot be directly touched from the bathtub or shower.
• Device must not be installed above bathtub!
250mm