Power Indicator LED
The Unit features one power indication LED on the front panel:
1. Not illuminated: The device is not powered.
2. Flashing green: The unit is receiving power but not data, or the unit has not been configured
correctly.
3. Solid green: The unit is operational. Power supply and network traffic are functional.
Signal LED
Six LEDs located in the center of the front panel act as audio signal identifiers for the six input channels
and are useful for setting optimum signal levels. Each LED has four states. Please see the table below for
the signal mapping to each of the LEDs. Detailed metering of current output levels can be obtained in real
time via the Vocia software interface.
Red
Signal above clip threshold>
-2dbFS
Control LEDs
The control LEDs signal the current state of the control I/Os. The first four are input status indicators, and
the second four are output status indicators.
Amber
Relays are energized
Amber
Signal above nominal but below
clip threshold
> -18dBFS
< -3dBFS
Above input threshold
Signal above minimum but below
nominal threshold
Green
Dark
Not active
VI-6 Front
Green
Signal below minimum
> -48dBFS
< -48dBFS
< -19dBFS
Dark
threshold