Application
Operation is possible in conjunction with:
- Pressurized storage heaters
- Thermally controlled instantaneous heaters
- Hydraulically controlled instantaneous heaters
Operation with low-pressure storage heaters
(displacement water heaters) is not possible.
Specifications
• Max. flow
• Flow pressure
- min.
- recommended
- greater than 72.5 psi, fit pressure
reducing valve
• Max. operating pressure
• Test pressure
• Temperature
- max. (hot water inlet)
• Water connection
Note
Major pressure differences between hot and cold
water supply should be avoided.
1
English
8.3 L/min or 2.2 gpm/60 psi
7.25 psi
14.5 - 72.5 psi
145 psi
232 psi
176 °F
cold - RH
hot - LH
Installation
Flush pipes thoroughly.
Installation and connection, see fold-out page III,
Fig. [1], [2] and [3].
Fit swivel spout, see Fig. [1].
Refer to the dimensional drawing on fold-out page I.
Open cold and hot-water supply and check
connections for leakage!
Maintenance
Inspect and clean all parts, replace as necessary and
grease with special grease (order no. 18 012).
Shut off cold and hot water supply!
I. Replacing the headpart, see Fig. [4].
1. Remove handle (45 603).
2. Unscrew screw (B) and pull off snap insert (C).
3. Unscrew headpart (D) using a 17mm socket wrench.
4. Change either complete headpart (D) or O-ring (E).
Observe the different replacement part numbers of
the headparts, see fold-out page II.
II. Flow regulator, see fold-out page II.
Unscrew and clean flow regulator (13 935).
Assemble in reverse order.
Replacement parts, see fold-out page II ( * = special
accessories).
Care
Instructions for care of this single lever faucet will be
found in the Limited Warranty supplement.