Ordinary Maintenance - Costan BATIK Instrucciones De Uso Para El Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 47
Modello - Modèle - Model
Modell - Modelo - Modelo
Fabbricante - Constructeur - Manufacturer
Hersteller - Fabricante - Fabricante
• do not lay heavy weights on the showcase's top surface (fig. 12).
LIGHTING
A switch located on the front of the case (see fig. 5, page 16) controls cabinet lights.
DEMIST HEATING ELEMENT (optional)
These showcases are equipped with a ventilation system that prevents the formation of mist on the
front glazing. When excessive ambient moisture causes mist on the glasses, a pilot-lamp switch
located on the rear control panel (see picture 7, page 19) can be turned on, which controls a demist
heater. The demist heater goes off automatically after one hour (pilot-lamp switch off) but can be
turned on again by pressing the switch button.
It is however possible to change heater operation times. To this purpose, contact the nearest after-
sales service.
DEFROSTING
The number and duration of defrosts are factory-set.
The user must never alter their adjustment.
Defrost-water is collected by a drain tube and conveyed into a drainage system. Periodically check
that defrost water flows off normally. Otherwise, unclog by the use of a pointless flexible probe.
9. PRESCRIPTIONS AND RESTRICTIONS
KEEPING PHARMACEUTICAL PRODUCTS, GLASS BOTTLES OR FLASKS IN THE SHOWCASE IS
STRICTLY FORBIDDEN as they could get broken and entail a safety hazard (fig. 13).
Resting the unpackaged food items directly on the decks should be avoided; use suitable food con-
tainers instead.
DO NOT REMOVE COVERS OR PANELS WHEN IT REQUIRES THE USE OF TOOLS AND ESPECIALLY
DO NOT REMOVE THE ELECTRIC CONTROL BOARD COVER.
Do not expose the showcase to atmospheric agents.
Do not spill water directly or indirectly on the showcase (fig. 16). Do not touch the machine with
damp or wet hands or feet; do not use it while barefoot (fig. 15).
ATTENTION: The refrigerating system does not alter defrost water in any way, which is the product
of the steam contained in the air circulating inside the showcase. Defrost water and wash water
may nonetheless mix with pollutants deriving from the products preserved in the appliance, from
preservation means, from product remains, from the accidental crush of recipients containing li-
quids or from the use of improper detergents (see section 10 point 1).
THE WATER PRODUCED BY THE SYSTEM MUST THEREFORE BE DISPOSED OF THROUGH A SEWER
OR PURIFICATION SYSTEM IN COMPLIANCE WITH THE REGULATIONS IN FORCE.
ANY OTHER USE NOT EXPLICITLY MENTIONED IN THIS BOOKLET MUST BE CONSIDERED AS HA-
ZARDOUS. THE MANUFACTURER DISCLAIMS ALL LIABILITY FOR ANY DAMAGE RESULTING FROM
IMPROPER, INCORRECT OR UNREASONABLE USE.

10. ORDINARY MAINTENANCE

ATTENTION! BEFORE MAINTENANCE OR CLEANING, DISCONNECT THE REFRIGERATOR FROM THE
ELECTRICAL POWER SUPPLY USING THE WALL MAIN CUTOFF SWITCH (fig. 18).
BATIK
VELNSxx
Epta Spa - Unità locale: Via degli Alpini 14 - 32020 Limana (BL)
ITALIA Tel. 0437/9681 Telefax 0437/967434
38/59
PAGE:
UM000483
N° DOC.

Publicidad

Tabla de contenido
loading