FloodStop by OnSite PRO
™
Leak Detection & Automatic
Water Shut-off System
Washing Machine Kit -
FS3/4H-90 & FS3/4H
FloodStop Washing Machine Kit
Congratulations on your purchase of a FloodStop by OnSite PRO
electronic water leak detection and automatic water shut-off kit for
washing machines. This product has been designed to give you years
of reliable service and minimize home water damage by detecting water
leaks and automatically shutting off the water supply.
To ensure proper installation and to maximize the performance of your
FloodStop water leak detection system, please read this manual
thoroughly.
PLEASE READ CAREFULLY BEFORE PROCEEDING:
If a leak is detected, the FloodStop Valves will shut off the water going
to the washing machine. This will stop the continuous flow of water from
the water supply valve to the washing machine. However, all or some of
the water that is already in the washing machine and hoses may still leak
out onto the floor.
NOTE: This unit was shipped with an installation and operating manual
that contains important information about its operation. If you are
installing this unit for use by others, we recommend you leave this
manual – or a copy of it – with the user.
Washing Machine Kit
FEATURES:
• Control Panel has easy to read, lighted function buttons
• AC Power with battery backup – For continued operation in the
event of power outages
• Solid brass, full port motorized ball valves for dependable, long
lasting performance
• Valves automatically shut-off the water supply when a leak is
detected
• Automatic monthly maintenance cycling of the valves to ensure
reliable operation
• Valves can be opened and closed with the touch of a button
• Activates an audible alarm when a leak is detected
• Mute button to silence the audible alarm
• Can be reset and reused continuously with the touch of a button
• Can be tested at any time with the touch of a button
• Can accommodate additional water leak sensors
• 1 Year Limited Warranty
FloodStop Washing Machine Kit
This Package Contains:
Installation and
FloodStop
A (2)
Operating
Valves (3/4" FHT x 3/4" MHT)
B (1) Control Panel
Manual
C (1) Leak Sensor with Paper Sleeve
D (1) AC Adaptor
E (1) Wire Harness
F (1) Hook & Loop Mounting Pad
G (2) Mounting Screws with Anchors
C
Check to make sure everything in the package matches the Contents Listing above.
Read the instructions thoroughly before installing or operating the FloodStop system.
Warning: Do not put finger(s) inside FloodStop Valves. Risk of serious injury may occur.
Caution: Do not grip plastic motor drive for leverage when tightening FloodStop Valves.
Installation
© 2012 OnSite PRO Inc.
STOP: Read the instructions thoroughly before installing or operating the
FloodStop System. The FloodStop Valves get installed directly to your existing
valves. If you are not sure how to install the FloodStop Valves to your existing water
™
lines, we recommend that you contact a licensed Plumber.
WARNING:
- For use with water only.
- Do not install on gas line.
Installation
1. Shut off the hot and cold valves that supply water to
your washing machine.
2. Remove the hot and cold washing machine hoses
from both valves. Mark the hoses so you know
which hose goes to which valve.
NOTE: Do not remove hoses from washing machine.
Motorized Brass
B
A
F
D
G
E
1.
2.
5.
3. Your existing hot and cold manual shut-off
shut-off
valves will have outlets that either face you,
valve
or face downward.
A. If the outlets face you: Hand tighten
the FloodStop Valves to the manual
shut-off valves so their outlets point
downward as shown in the diagram.
Note that a washer has been
pre-assembled in each coupling nut.
B. If the outlets face downward: Hand
tighten the FloodStop Valves to the
3A.
manual shut-off valves so their outlets
point sideways as shown in the diagram.
Note that a washer has been
4.
pre-assembled in each coupling nut.
4. Hand tighten the hot and cold washing
machine hoses to the correct FloodStop
Valve.
5. Lightly wrench tighten all connections 1/4 turn, or until
5.
snug. Do not over tighten.
6. Turn on the hot and cold manual shut-off valves
6.
and check for leaks.
7. Mount the FloodStop Control Panel in an easily
7.
accessible location within 30 inches of the FloodStop
Valves. You may mount the panel using the screws and
anchors, or Hook & Loop Mounting Pad provided. When
using the Hook & Loop Mounting Pad, make sure the
adhesive is put on a clean, dry surface.
NOTE: Depending on the location you pick, and the dis-
tance between the hot and cold shut-off valves, you may
need to purchase two (2) FloodStop Control Panel to Valve
Extension Wires, Model # CEXT-09 (available where you
purchased your FloodStop System).
8.
8. With the contacts of the wire harness connector facing
you, plug the 6-pin connector end of the Wire Harness
into the bottom of the Control Panel.
6 pin connector
shut-off
valve
3B.
(NO) Output &
Sensitivity Adj