9. Take the 2 short wires coming from the Control Panel
9.
and connect each one to a FloodStop Valve (make
sure the arrow on the side of the plugs line up with
each other). It does not matter which wire gets
connected to which FloodStop Valve.
NOTE: The Leak Sensor comes with a Paper Sleeve. If the
Leak Sensor is going to make contact with the washing
machine, or any other piece of metal, make sure you leave
the Paper Sleeve on. If the Leak Sensor makes contact
with metal, it will signal the FloodStop Valve to shut off. The
Paper Sleeve acts as a barrier between the Leak Sensor
and the metal. When the Paper Sleeve becomes wet, it will
signal the FloodStop Valve to shut off. If the Leak Sensor
will not be contacting metal, you may remove the Paper
Sleeve.
10.
10. Connect plug on end of long flat wire coming from
Control Panel to either set of prongs on the Leak
Sensor, pushing until plug snaps in place.
Then
place Leak Sensor on the floor behind the washing
machine.
NOTE: Additional Leak Sensors can be connected together
for added protection. For additional Leak Sensors, pur-
chase FloodStop Water Leak Sensor, Model # XS-01 (avail-
able where you purchased your FloodStop System).
CAUTION: Do not place Leak Sensor or cord in a walkway,
or other location that may cause someone to trip and fall.
11.
11. Plug the pin on the end of AC Adaptor cord into the
bottom of the Control Panel, and then plug the AC
Adaptor into a wall outlet. Green indicator lights will start
to flash, showing you have power. Note that a red low
battery indicator light will also flash about every 30
seconds, and the unit will beep once a minute until the
batteries are installed.
NOTE: If a nearby wall outlet is not available you will need to
purchase a thin low voltage FloodStop "AC Adaptor
Extension Wire" Model # WAE-09 (available where you
purchased your FloodStop System). This wire extends the
length of the AC Adaptor cord.
CAUTION: Do not plug the AC Adaptor into an extension cord.
12.
12. FloodStop has a battery backup system that allows
the unit to continue working in the event that you have a
power outage. To set up the backup system, open the
front of the Control Panel and install 4 fresh AA alkaline
batteries (batteries not included). The low battery
indicator light will now stop flashing and the beep
will stop.
CAUTION: Replace batteries once a year or sooner as
necessary. If batteries need to be changed sooner, a red low
battery indicator light will flash, and a beep will sound.
How to Operate your Control Panel
1. Top button opens FloodStop Valve
2. Middle button closes FloodStop Valve
3. Bottom button mutes the audible alarm that
sounds when a leak is detected
3
2
1
Testing Your FloodStop System
FloodStop
1. Push the Open button to make sure
Valve is open.
• When the
FloodStop
Valve is opening or closing, you will hear the valve motor operating for a
few seconds.
2. Saturate a rag with water and squeeze over Leak Sensor, or dip the Leak Sensor into a small bucket of
water. Once the Leak Sensor is wet, it will signal the
FloodStop
Valve to close, then an audible alarm will
sound and a red light will flash.
• Push the Mute button to silence the alarm, and note that
the red light will continue to flash. This means
the
FloodStop
Valve is closed, and will remain closed until you push the Open button.
• Before the
FloodStop
Valve can be opened, the Leak Sensor needs to be dry. There is no need to
unplug the unit when drying off the Leak Sensor.
• The water test can be done with the paper sleeve still on
the Leak Sensor. Note that the paper sleeve is
reusable, but once it gets wet you will need to let it air dry flat before placing it back on the Leak Sensor.
Helpful Hints
• If the Leak Sensor Paper Sleeve is misplaced or becomes unusable, a paper towel can be used
in its place.
• The Leak Sensor has two sets of prongs so you can connect additional Leak Sensors. You can
link them together so they are positioned at different locations around your laundry area.
• Once a month, the FloodStop Valves will automatically close and open by themselves. The
Control Panel is programmed to run this cycle to ensure that the valves continue to function
properly in the event that they need to shut off the water.
• Hanging Wires may be tied together using twist ties (Not provided).
Troubleshooting
Problem
What to Check
Status light does not light
- Make sure there is power to the outlet.
- Unplug AC Adaptor cord from Control
Panel and plug back in.
- If an AC Adaptor extension wire was used,
unplug both ends and reconnect.
- Make sure fresh batteries are in the Control
Panel.
FloodStop Valves closed but now will not open
- Make sure both sides of Leak Sensor are
dry.
The alarm goes off for no apparent reason
- Leak Sensor is touching metal, or the
concrete is sweating causing high humidity.
Correct the problem by placing the Paper
Sleeve on the Leak Sensor, or use a paper
towel as a barrier.
Problem
What to Check
Only one FloodStop Valve operates
- Unplug 6-pin connector from Control Panel
and reconnect.
- Locate plug connection between Control
Panel and the FloodStop Valve that does
not operate. Unplug the connection and
reconnect, making sure arrows on side of
plugs line up.
- Push the Close button and wait a few
seconds. Then push the Open button.
Neither FloodStop Valve operates
- Make sure both sides of Leak Sensor are dry.
- Make sure there is power to the outlet.
- Unplug AC Adaptor cord from Control Panel
and plug back in.
- Unplug 6-pin connector from Control Panel
and reconnect.
- Locate plug connection between Control
Panel and each of the FloodStop Valves.
Unplug both connections and reconnect,
making sure arrows on side of plugs line up.
- If an AC Adaptor extension wire was used,
unplug both ends and reconnect.
- Make sure fresh batteries are in the Control Panel.
Troubleshooting
Problem
What to Check
You turn on the washing machine, but no
- Make sure both sides of Leak Sensor are
water flows
dry, then push the OPEN button to make
sure FloodStop Valves are open.
- Make sure the hot and cold manual shut-off
valves are open.
Leak Sensor becomes wet but FloodStop
- Unplug long flat wire from Leak Sensor and
Valves do not close
reconnect.
- Make sure there is power to the outlet.
- Unplug AC Adaptor cord from Control Panel
and plug back in.
- Unplug 6-pin connector from Control Panel
and reconnect.
- Locate plug connection between Control
Panel and each of the FloodStop Valves.
Unplug both connections and reconnect,
making sure arrows on side of plugs line up.
- If an AC Adaptor extension wire was used,
unplug both ends and reconnect.
- Make sure fresh batteries are in the Control
Panel.
Manual Operation of FloodStop Valve
1. Unplug the connection between the Control Panel and the FloodStop Valve.
2. Pull the plastic motor cover off the FloodStop Valve and slide it down the wire until it stops at the
plug. Note that no tools are needed to remove the cover.
3. Use a marker and draw a line across the top of the plastic motor housing. This way once the motor
is removed you will know how to reposition it for assembly.
4. Remove the 4 screws using a Phillips head screwdriver.
5. Place thumb and finger on plastic gear and rotate clockwise to open valve or counter clockwise to
close it. Do not use tools to manually open or close valve.
1 Year Limited Warranty
OnSite PRO Inc. warrants the enclosed FloodStop product to be free from defects in materials or workmanship, under
normal use and service, for a period of one (1) years from the date of purchase. If at any time
during the warranty period the product is determined to be defective, OnSite PRO Inc. shall repair or replace it (at
our option). The warranty is limited to defective parts as stated. All costs of removal and installation of the FloodStop
product, including the replacement of warranty parts, are the responsibility of the purchaser. The
manufacturer shall not be liable for incidental, consequential, or special damages arising at, or in connection with
product use or performance, except as may otherwise be accorded by law. Some states do not allow the exclusion
limitation of incidental or consequential damages, so the limitation may not apply to you. Any damage to this
FloodStop product as a result of misuse, abuse, neglect, accident, improper installation, or any use violating the
instruction manual furnished by us will void this warranty. This warranty does not cover damages or loss caused by
defects, and the owner's use of the FloodStop product confirms the understanding that this product does not
constitute an insurance policy, and is only a loss mitigation product used to reduce the risk of water damage.
To obtain warranty service, call our Customer Service Department at 1-800-667-4833, or e-mail us at customer
sales@getfloodstop.com. You may also send the product and original dated receipt, prepaid US postage to:
OnSite PRO Inc. 28222 Shadowland Circle, Modjeska Canyon, CA 92676, Attention: Customer Service.
FloodStop Washing Machine Kit
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy, and if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
• Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
• Consult the dealer or an experienced radio/TV technician for help.

Publicidad

loading

Este manual también es adecuado para:

Floodstop fs3/4h