Warning! Before connecting to the mains supply ensure that mains voltage (V) and frequency (Hz) corresponds to
the parameters on the rating plate inside the cooker hood.
Warning! The equipment is not intended for use by persons (including children) with reduced physical, sensory
or mental ability.
Instalation
Please take off the front cover using a small cross screw driver. Remove a small screw in the low part of the fan
showed in the (pic.1). The fan should be fitted instead of the ventilation grill or in the place prepared exactly for
his kind of fans. For installation please use the holes situated in a fan body. In order to use the fan please pull the
cord to switch it on and off. The fans in basic version with terminal block only or with the electronic control systems
(T, FT, HT) should be connected with the wiring system directly. Please take off the small cover showed in the using
a small cross screw driver. The terminal block is situated under the cover and depending of the fan version there
are 2 or 3 units to connect the fan with, LN or NLS (pic.4).
Please note that all wiring must comply with current I.E.E. Wiring Regulations, installation must be made by a
qualified electrician.
•
The fixed cover should evenly adhere to the wall panel to avoid distortion.
•
For the fans with the permanent electrical connection, the electrical installation must have a switch with
the distance between the contacts of all poles of not less than 3 mm.
The fans extended with the electronic control systems have a mounted timer. Fan activation depends on the
control system.
WP - pull and switch
The fans with a pull switch and 1,9m cable with a plug should be plugged into the electric socket ~230V. The fan
with a pull switcher enables temporary starting and stopping of the fan by pulling the strip coming out of the fan.
Attention: Before commencing any electrical work or making any adjustments with the fans in basic version with
terminal block only or with the electronic control systems please ensure the mains isolator switch on the consumer
unit / fuse board is in the 'OFF' position, to prevent the possibility of electric shock.
Security Attention! In the case of damage of the electric wiring, all repairs should be carried in the Service Centre.
Technical information
Voltage (V)
Phase (Hz)
Power (W)
Suction power (m
/h)
3
Noise level (dB)
Security Level
Speed (min)
Weight (kg)
Technical information
Voltage (V)
Phase (Hz)
Power (W)
Suction power (m
/h)
3
Noise level (dB)
Security Level
Speed (min)
Weight (kg)
9799-140
da 9799-150
9799-141
a 9799-155
19
100
39
2550
0,5
0,55
9799-140X
9799-121
220-230
220
15
75
32
IPX4
IP-44
2550
0,35
9799-156
9799-142
9799-157
220-230
50
20
150
42
IP-44
2360
0,59
9799-170
240
50
15
80
60
33
6
9799-143
2100
0,67
0,64
9799-171
240
15
110
36
IPX4
-
-
9799-158
9799-159
24
300
49
0,7
9799-172
240
160
38