T- timer
The fan is activated after the light is switched on (1st version of fan installation) or after pressing the switcher (2nd version of fan
installation) look in the (pic.4). After turning off the light or switcher the fan works for the time allocated by the adjustable screw.
Fan models with timer, set the required length of time for the fan to run after the fan is switched off by first ensuring the mains
power is isolated,
and then with the cover of the fan removed insert a small screwdriver into the aperture marked and slowly rotate clockwise or
anti-clockwise to increase or decrease the timer setting from 0-30 minutes (pic.3).
Humidity sensor HT
The fan is activated automatically after receiving expected humidity threshold or switching on the light or switcher connected. The
fan works until the switcher or light is on or the humidity above the expected threshold. After turning off the light or switcher and
when the humidity is below the expected threshold the fan works for the time allocated by the adjustable screw. The time interval
is between 0 - 30 min. The fan has adjustable humidity knob and the humidity threshold could be set up between 30-80%. Please
set up all required parameters before use.
The humidity sensor and adjustable knobs are situated in the electronic PCB. After connecting the fan with the wiring system ~220-
230V, the right knob should be turned on position 0min. and the left one on the low humidity. These settings should activate the fan:
•
The fan works until the humidity threshold is reached by turning the screw very slowly to high humidity position. When the
local humidity level is reached the fan should stop after 2 seconds.
•
Then the humidity knob should be turned 10omore to high humidity position. If the fan is not activated it means that the
humidity threshold is below 30%. It is possible in winter time when the heaters make the air inside the house very dry. Please
leave the humidity knob in position low and set up the timer knob in expected position. The fan should be tested by
blowing at the humidity sensor from distance about 10cm. In this moment they should start working (pic.3).
Dimentions
9799-140
(mm)
9799-141
A
141
B
131
C
84
D
99
E
11
Dimentions
9799-140X
(mm)
A
B
C
D
E
Guarantee
Producer guarantee on EXTRA is – 24 months.
In the case of damages contact the place of trade.
The guarantee does not cover:
1. noted mechanical or other damages
2. mechanical or other damages caused by incorrect or improper usage, misuse, abuse or neglect
3. mechanical or other damages caused by incorrect installation or by product's incorrect fitting to insufficient
or unsuitable power
4. mechanical or other damages caused by ignoring the instruction manual conditions
A guarantee does not cover natural wear of the product.
Guarantee
Information for Users on Disposal of Old Equipment. This symbol indicates that the electrical and
electronic equipment should not be disposed of as general household waste at its end-of-life.
Instead, the products should be handed over to the appliance collection points for the recycling
of electrical and electronic equipment, recovery and recycling in accordance with your national
legislation and the Directive 2002/96/EC and 2006/66/EC.
da 9799-150
a
9799-155
141
131
84
99
28
9799-121
120
155
120
165
70
47
98
98
20
40
9799-156
9799-142
9799-157
150
150
162
162
88
88
119
119
12
29
9799-170
9799-172
163
163
70
78-98-118
27
7
9799-143
170
183
88
149
14
A
D
B
EN
9799-158
9799-159
170
183
88
149
32
C
E