Filtering Oil; Resetting The Appliance - Ndustrio 091FR1ED Manual De Uso E Instalación

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

FILTERING OIL

To carry out this operation, proceed as follows.
Important
Before proceeding, allow the appliance to
cool for 10÷15 min., so that the oil reaches
a temperature between 50÷120°C.
1 - Open the hatch (A).
2 - Fit the extension (B) onto the tap (C).
3 - Place the container (D) and the filter (E), both
available as optionals, underneath the exten-
sion (B).
4 - Turn on the tap (C) to empty the well.
5 - Turn off the tap (C) on completion of the opera-
tion.
Caution - warning
Do not dump oil in the environment; dispose
of it in accordance with the laws in force in
the country of use.

RESETTING THE APPLIANCE

Important
There are no indicator devices to signal
that the thermostat has been tripped.
If the safety thermostat is tripped, the appliance has
to be restored to the initial working conditions as fol-
lows.
1 - Allow the oil to cool to 30÷40°C.
2 - Open the hatch (A).
3 - Press the button (B) of the safety thermostat
tripped to restore the electricity supply.
4 - Close the hatch (A).