INSTALLATION INSTRUCTIONS
NOTE: Assemble pipe and fittings without glue to
check for proper fit.
9. Connect pumps, pipe, check valve and fittings
to verify the position in the sump pit. Once fitting
is correct, glue all joints using 2-step PVC glue
and primer.
Both the primary pump and DC backup pumps
will require check valves in the discharge pipes
for proper operation. BOTH check valves should
be located between pump discharge and where
the discharge pipes are joined.
10. Loosely attach the DC pump switch clamp to
the DC pump discharge pipe. Slide the switch
mounting bracket under the switch clamp.
Adjust the position of the switch so that the 'ON'
level of the DC pump is above the 'ON' level of
the primary pump. Tighten the mounting clamp
of the DC pump switch in the correct location.
11. Place a fully-charged, deep-cycle marine battery
inside the battery box. Connect the leads inside
the battery box from the controller to the battery:
WARNING: Connecting the wires to the wrong
terminals on the battery may cause damage to the
controller.
Red (+) to battery Red (+)
Black (-) to battery Black (-)
NOTE: The alarm will sound after connecting
the battery. It will continue to sound until all
connections are made and the float switch is in the
down position.
NOTE: Be sure the battery box ventilation holes are
unobstructed. Battery control box must be set up in a
well-ventilated area, away from any smoke, flames or
pilot lights.
8
© 2020. All rights reserved.
9
Check valve
located in
backup pump
discharge
10
Clamp
Mounting
Bracket
11
Joined
discharge
pipes
Check valve
located in
primary
pump
discharge
DC Pump
Switch