CONFIGURATION

Warnings

The lighting system (natural and / or artificial) of the area of preparation for use must ensure the following
minimum illuminance values: 200 lux.
All products are tested and fine-tuned by the manufacturer before shipping and delivery to the customer.
The product has been designed, manufactured and tested to meet all specific standards (see the declaration
of conformity), if configured in a workmanlike manner.
If the configuration, use and / or maintenance of the bio-fireplace are not carried out in a workmanlike manner,
anomalies may occur during use, and safety problems may also occur. Inappropriate configuration and
maintenance will void the warranty terms.
ATTENTION
THE BIO FIREPLACE CAN ONLY BE STARTED AFTER IT HAS BEEN CONFIGURED
CORRECTLY.
Before configuring and putting the bio-fireplace into operation, completely remove any protection from dust or
humidity and any packaging material..
Only use the bioethanol bio-fireplace in sufficiently ventilated rooms of at least 10 m² (volume of at
least 30 m³). Combustion draws the necessary air from the environment, this must always be
reintegrated into the environment where the appliance is positioned through special air intakes
which must be protected by suitable grills, as indicated by the UNI 10683 standard. has obstructed
the passage of air.

Preliminary checks

Check for any damage
Check that the various parts of the bio-fireplace do not show physical damage due to bumps, tears or
abrasions.
Check in particular:
• that there are no signs or dents, indicative of impacts occurred during transport;
Damage Reporting Procedure
If any damage is found, stop the procedure in progress and report the nature of the damage to the
manufacturer's customer support office.
Configuration
• Place the product in an environment that complies with the requirements indicated in the "Locations"
paragraph.
• Remove the painted steel body of the bio-fireplace from the package
• Free the burner from the protective film
• Refill the burner according to the instructions given in the paragraph "Bioethanol refill"
• Remove the borosilicate glass from the package
• Carefully place the borosilicate glass over the painted steel structure of the bio-fireplace, making sure to
insert the glass in the appropriate slots.
• Turn on the bio-fireplace following the requirements indicated in the paragraph "Use Procedures"
34