BM 2610925943 6-05
NO USER SERVICE-ABLE
!
WARNING
PARTS INSIDE. Preventive
maintenance performed by unauthorized
personnel may result in misplacing of
internal wires and components which
could cause serious hazard. We recom-
mend that all tool service be performed by a
Bosch Factory Service Center or Authorized
Bosch Service Station. SERVICEMEN:
Disconnect tool and/or charger from power
source before servicing.
BATTERIES
Be alert for battery packs that are nearing
their end of life. If you notice decreased
tool performance or significantly shorter
running time between charges then it is time
to replace the battery pack. Failure to do so
can cause the tool to operate improperly or
damage the charger.
Long term battery storage should be in
the discharged state. Battery packs last
longer and re-charge better when they are
stored discharged. Remember to fully re-
charge battery packs before using after
prolonged storage.

TOOL LUBRICATION

Your Bosch tool has been properly lubricated
and is ready for use.
If an extension cord is
!
WARNING
necessary, a cord with
adequate size conductors that is capable
of carrying the current necessary for your
tool must be used. This will prevent
excessive voltage drop, loss of power or
overheating. Grounded tools must use 3-wire
extension cords that have 3-prong plugs and
receptacles
.
NOTE: The smaller the gauge number, the
heavier the cord.
(*= standard equipment)
(**= optional accessories)
* Carrying case (Model 52324 only)
** Circle and parallel cutting guide
6/10/05
10:25 AM
Maintenance
Service
Accessories
Page 15
D.C. MOTORS
The motor in your tool has been engineered
for many hours of dependable service. To
maintain peak efficiency of the motor, we
recommend it be examined every six
months. Only a genuine Bosch replacement
motor specially designed for your tool should
be used.
Cleaning
To avoid accidents, always
!
WARNING
disconnect the tool and/or
charger from the power supply before
cleaning. The tool may be cleaned most
effectively with compressed dry air. Always
wear safety goggles when cleaning tools
with compressed air.
Ventilation openings and switch levers must
be kept clean and free of foreign matter. Do
not attempt to clean by inserting pointed
objects through opening.
Certain cleaning agents
!
CAUTION
and
plastic parts. Some of these are: gasoline,
carbon tetrachloride, chlorinated cleaning
solvents, ammonia and household detergents
that contain ammonia.
RECOMMENDED SIZES OF EXTENSION CORDS
120 VOLT ALTERNATING CURRENT TOOLS
Cord Size in A.W.G.
Tool's
Ampere
Cord Length in Feet
Rating
25
50
3-6
18
16
6-8
18
16
8-10
18
16
10-12
16
16
12-16
14
12
** 15 minute charger
** 30 minute charger (single bay)
** 30 minute charger (dual bay)
** 1 hour charger
-15-
solvents
damage
Wire Sizes in mm
Cord Length in Meters
100 150
15
30
60
120
16
14
0.75 0.75 1.5
2.5
14
12
0.75 1.0 2.5
4.0
14
12
0.75 1.0 2.5
4.0
14
12
1.0 2.5 4.0
2