COMMON TROUBLESHOOTING

5.1
Air leakage at the connection between pressure gauge and cylinder valve
/ Air leakage at the connection between 8mm inflation plug and the primary
pressure reducing valve?
Answer: Use a wrench to tighten the pressure gauge and the
inflation plug to eliminate the malfunction.
5.2
Air leakage at the connection between the primary pressure reducing valve
and the cylinder?
Answer: Replace the rubber ring at the bottom of the primary
pressure reducing valve and tighten to the cylinder to eliminate
the malfunction.
5.3
Air leakage at the port of inflation plug?
Answer: Remove the inflation plug, take off the O-shaped rubber
ring at the bottom and clean/replace with clean water, wipe off the
water and reinstall back to the original place. Make it tightened to
eliminate the malfunction.