Fault
Insufficient water
Crossflow, hot water is forced into
cold water pipe, or vice versa,
when mixer is closed
Spout temperature does not corre-
spond with the temperature set
Temperature regulation not pos-
sible
Shower or spout dripping
Instantaneous heater didn't work
with thermostat
English
Cause
- Supply pressure inadequate
- Filter are dirty
- Shower filter seal dirty
- Backflow preventers dirty or lea-
king
- Thermostat has not been adjus-
ted
- Hot water temperature too low
- MTC-thermo cartridge calcified
- Dirt or sedaimentation on valve
seat, shut-off unit damaged
- Flow limiter in handshower isn't
removed
- Filter are dirty
- Non return valve didn't move
back
Remedy
- Check mains pressure
- Clean filter in front of the mixer
and on the MTC-thermo cart-
ridge
- Clean filter seal between sho-
wer and hose
- Clean backflow preventers, ex-
change if necessary
- Adjust thermostat
- Increase hot water temperature
to 42 °C to 65 °C
- Exchange MTC-thermo cartridge
- Clean or exchange shut-off unit
- Remove flow limiter
- Clean the filter/exchange filter
- Exchange non return valves