This Package Contains:
1 - EMS1000
1 - Grommet
2 - Self tapping screws
3 - Cable ties
1 - Packet Dielectric Grease/Corrosion Preventer
• Always wear personal protective equipment (goggles, gloves, etc.) to
• Be sure the battery is disconnected from the charger to ensure the cells
• Not recommended for use with battery additives.
• Read instructions in entirety before beginning the installation.
STEP 1: PLAN
The electrolyte probe must be at least 4
cells to the positive side of the negative
(black) wire connection. Take this into
consideration when planning your
installation. The sensor needs 8-12 volts
to function properly.
STEP 2: DRILL
Choose a cell where the level probe will
be inserted. (Reminder: you must have
at least 4 cells to the positive from
the black (negative) wire.) Drill a 1/2"
hole in the cover of the level probe cell.
The hole should be drilled between the
vent opening and the edge of the cell to
avoid cell internals. Do not drill into the
battery plates. Make sure the probe does
not touch the internal straps.
STEP 3: TRIM PROBE
Cut the probe to length. When fully
inserted, the tip of the probe should be
approximately 1/4" above the plates or
moss shield. Insert the grommet into the
hole and then insert the probe through
the hole in the grommet.
Intended for Installation by Qualified Personnel
protect yourself from sulfuric acid.
are not gassing before proceeding.
Installing the i-Lite
Part # EMS1000
Tools required for installation:
• Towel to wipe down the top of the battery
• Drill
• Phillips screwdriver bit
• 1/2" (12 mm) drill bit
• Insulated wire cutters
BLACK
Example of 18 Cell Installation
Example of Drill Zone
Grommet
¼" (6 mm)
Trim end of probe 1/4"
above plates or moss shield
Sensor
PROBE
RED