STEP 4: CONNECT
Connect the RED wire to the POSITIVE side of the cell where the probe is installed. Count four (4)
cells in the direction of the main negative post, including the cell the probe is installed in and
connect the BLACK wire to the NEGATIVE side of the fourth cell.
BLACK
PROBE
RED
This is an example of where to connect the wires on an 18 cell battery
STEP 5: SECURE HOUSING
Secure the sensor light housing using cable ties supplied. The example shows a method of
attaching the housing to an intercell connector using the supplied cable tie. Make sure wires are
secured so they cannot be snagged or pulled.
Tie down example for electronic housing
LED COLOR CODES
Blinking Green - Battery is OK
Blinking Red - Add water only after the next full charge