Granit BT 400 Manual Del Usuario página 10

Batería & analizador del sistema eléctrico
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 44
6. Press «ENTER» for the charging system with
accessory loads. Turn on the blower to high
(heat), high beam headlights, and rear defogger.
Do not use cyclical loads such as air conditioning
or windshield wipers.
7. When testing older model diesel engines, the
users need to run up the engine to 2500 rpm for
15 secs.
8. Press «ENTER» to read the ripple from the charging system to the battery.
One of the three testing results will be displayed along with the actual testing
measured.
RIPPLE DETECTED NORMAL
Diodes function well in the alternator / starter.
NO RIPPLE DETECT
Ripple is not detected.
EXCESS RIPPLE DETECTED
One or more diodes in the alternator are not
functioning or there is stator damage. Check to
ensure the alternator mounting is sturdy and
that the belts are in good shape and functioning
properly. If the mounting and belts are good,
replace the alternator.
9. Press the «ENTER» key to continue the charging system with accessory
loads. One of the three results will be displayed along with the actual testing
measured.
CHARGING SYSTEM HIGH WHEN
TEST WITH ACCESSORY LOADS
The voltage output from the alternator to the
TURN ON LOADS
RUN ENGINE UP
TO 2500RPM 15
xx.xx V NORMAL
NO RIPPLE DETECT
ALT. LOAD VOLTS
10
PRESS ENTER
SEC
RIPPLE
DETECTED
PRESS ENTER
RIPPLE
DETECTED
xx.xx V HIGH
xx.xx V HIGH

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

5070011165

Tabla de contenido