SPECIFICATIONS

Gas Category: Propane under vapor pressure. This appliance should only be used
with 16.4 oz disposable propane cylinders (sold separately). It may be hazardous
to attempt to fit other types of gas canisters.
The LP-gas cylinder(s) used with this stove must be constructed and marked
in accordance with the specifications for LP-gas cylinders of the U.S. Department
of Transportation or Transport Canada, CAN/CSA B339.
Jet Size: 0.39mm Gas Consumption: 10,000 BTU/hr
LEAK CHECK
PROCEDURE
1. Perform Leak Checks outside, in a well-ventilated area.
2. Connect Fuel Regulator (4.1) to the Fuel Input port (4.2) located in the rear
of the left side of the stove by threading Coupling clockwise.
3. Connect Propane Cylinder (4.3) (sold separately) into Fuel regulator (4.1)
by threading clockwise in the orientation shown in Fig. 4.
4. Put soapy water on the gas connections between Propane Cylinder
and the Regulator as well as the Regulator and the Fuel Input Port.
Formation of bubbles indicate a gas leakage.
Do not check for leaks using a flame.
WARNING
WARNING
If a leak is detected, do not attempt ignition. Vapors can ignite
and cause serious injury. Remove fuel source immediately
and contact Customer Service.
5. If no leak is found, detach fuel source. Leak check is complete.