Honeywell Home PS1201A00 Instrucciones De Instalación página 4

Fuente de energía de repuesto para limpiadores electrónicos de aire
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

PS1201A00, PS1202A00 AND PS2401B12 REPLACEMENT POWER SUPPLIES FOR ELECTRONIC AIR CLEANERS
STEP 2:
Install new power supply.
4
1 INTERLOCK SWITCH.
2 SHORTING BAR FOR OZONE REDUCTION.
3 AIRFLOW SWITCH DISABLE JUMPER, R16.
AIRFLOW SWITCH PLUG, J3.
4 NEON LIGHT.
5 OPTIONAL W8600F AIR CLEANER MONITOR.
6 JUMPER LOCATION FOR IONIZER CURRENT SELECTION.
7 JUMPER LOCATION FOR IONIZER VOLTAGE SELECTION.
a. Position the P5 shorting bar for the size air cleaner you have.
b. Wire the power cord ground lead to the ground choke assembly using a wire nut. Secure ground con-
nection to the green ground screw on the wiring compartment barrier.
CHECKOUT
With all components in place, turn on the air cleaner switch and energize the system blower. Check the following
operation:
1. Be sure the neon light is on.
2. Turn off the system blower. The neon light should go off.
3. Turn the system blower back on. The neon light should come back on.
4. With the air cleaner energized, push the test button. A snapping sound indicates that collector section is
energized.
5. With a multispeed blower, repeat steps 2 through 4.
6. If operation is not as described, refer to Troubleshooting and Service section.
69-2673EFS—03
P3
BLACK
U4
J8
BLACK
2
P5
P4
P8
6
7
J4
POWER SUPPLY
3
5
J4
ORANGE
JUMPER
GRAY
VIOLET
BLACK
AIRFLOW SWITCH BOARD
BLACK COLLECTOR
RED IONIZER
RED
T1
0.25mA
0.9mA
1.05mA
1.29mA
1.65mA
2.1mA
BROWN
P2
P1
BLACK
1
BLACK
W4 W2 W1 W3
4
TEST
BUTTON
CONTACT
BOARD
BLACK
BLACK
GREEN
GROUND
GREEN
CHOKE
M32904A

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ps1202a00Ps2401b12

Tabla de contenido